Assessment of wear and periacetabular osteolysis using dual energy computed tomography on a pig cadaver to identify the lowest acceptable radiation dose

Sandgren, B. (author)
Karolinska Institute, Sweden
Skorpil, M. (author)
Karolinska Institutet,Karolinska Institute, Sweden
Nowik, P. (author)
Karolinska Institute, Sweden; Karolinska University Hospital, Sweden
show more...
Olivecrona, H. (author)
Karolinska Institute, Sweden
Crafoord, J. (author)
Karolinska Institute, Sweden; Ersta Hospital, Sweden
Weidenhielm, L. (author)
Karolinska Institutet,Karolinska Institute, Sweden; Karolinska Institute, Sweden
Persson, Anders (author)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping,Karolinska Institute, Sweden
show less...
 (creator_code:org_t)
BRITISH EDITORIAL SOC BONE JOINT SURGERY, 2016
2016
English.
In: Bone & Joint Research. - : BRITISH EDITORIAL SOC BONE JOINT SURGERY. - 2046-3758. ; 5:7, s. 307-313
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. Materials and Methods A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV. Results We could assess wear and PAO while substantially lowering the effective radiation dose to 0.7 mSv for a total pelvic view with an accuracy of around 0.5 mm for linear wear and 2 mm to 3 mm for PAO. Conclusion CT for detection of prosthetic wear and PAO could be used with clinically acceptable accuracy at a radiation exposure level equal to plain radiographic exposures.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Keyword

Low-dose dual-energy computed tomography; Wear; Osteolysis; Accuracy

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view