Personal smartphones for neonatal diagnostic imaging: A prospective crossover study

Westberg, Margreta (author)
Linköpings universitet,Medicinska fakulteten
Vasko, Theresia (author)
Linköpings universitet,Medicinska fakulteten
Owen, Louise S. (author)
Royal Womens Hospital, Australia
show more...
Bhatia, Risha (author)
Royal Childrens Hospital, Australia
Thio Lluch, Marta (author)
Royal Womens Hospital, Australia
Donath, Susan (author)
Murdoch Childrens Research Institute, Australia
Davis, Peter G. (author)
Royal Womens Hospital, Australia
Dawson, Jennifer A. (author)
Royal Womens Hospital, Australia
show less...
 (creator_code:org_t)
2017-02-14
2017
English.
In: Journal of Paediatrics and Child Health. - : WILEY. - 1034-4810 .- 1440-1754. ; 53:4, s. 343-347
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • AimNeonatal clinicians may be asked to review X-ray images when unable to directly access the original image. Transmitting an X-ray image to a smartphone is a technique increasingly being used by clinicians in a number of settings. Minimal data exist on its use in the neonatal setting. Our aim was to compare the ability of neonatal clinicians to correctly diagnose a pneumothorax from a chest radiograph (CXR) viewed on a smartphone, paralleled with the same image viewed on a computer screen. MethodsWe investigated the accuracy, sensitivity, specificity, positive predictive value and negative predicative value of two methods of viewing CXR images to diagnose pneumothorax, compared with a gold standard radiologist report. Clinicians were presented with 40 CXR images on two occasions, at least 1 week apart. Images were viewed once on a smartphone and once on a computer screen. Both the viewing method and viewing order of the images were randomised. The clinical details of the infant at the time the CXR was taken were provided, and participants were asked if a pneumothorax was present. ResultsTwenty-one clinicians viewed all CXR images using both viewing methods (840 paired observations). There was no difference in accuracy of detecting pneumothorax between viewing methods, 81% correctly identified a pneumothorax using the smartphone, versus 80% using the computer screen (P = 0.40 (95% CI), difference -4 to 1.5%). ConclusionDiagnosis of neonatal pneumothorax was as accurate using a smartphone as viewing CXR images displayed on a computer screen when clinicians were presented with X-rays with diagnosis of pneumothorax.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

infant; newborn; teleradiology; diagnostic accuracy; pneumothorax; smartphone

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view