SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-140036"
 

Search: onr:"swepub:oai:DiVA.org:liu-140036" > Fully automatic lef...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Fully automatic left ventricular myocardial strain estimation in 2D short-axis tagged magnetic resonance imaging

Morais, Pedro (author)
KULeuven University of Leuven, Belgium; ICVS 3Bs PT Govt Associate Lab, Portugal; University of Porto, Portugal; University of Minho, Portugal
Queiros, Sandro (author)
KULeuven University of Leuven, Belgium; ICVS 3Bs PT Govt Associate Lab, Portugal; University of Minho, Portugal
Heyde, Brecht (author)
KULeuven University of Leuven, Belgium
show more...
Engvall, Jan (author)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Dhooge, Jan (author)
KULeuven University of Leuven, Belgium
Vilaca, Joao L. (author)
ICVS 3Bs PT Govt Associate Lab, Portugal; DIGARC Polytech Institute Cavado and Ave, Portugal
show less...
 (creator_code:org_t)
2017-08-07
2017
English.
In: Physics in Medicine and Biology. - : IOP PUBLISHING LTD. - 0031-9155 .- 1361-6560. ; 62:17, s. 6899-6919
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Cardiovascular diseases are among the leading causes of death and frequently result in local myocardial dysfunction. Among the numerous imaging modalities available to detect these dysfunctional regions, cardiac deformation imaging through tagged magnetic resonance imaging (t-MRI) has been an attractive approach. Nevertheless, fully automatic analysis of these data sets is still challenging. In this work, we present a fully automatic framework to estimate left ventricular myocardial deformation from t-MRI. This strategy performs automatic myocardial segmentation based on B-spline explicit active surfaces, which are initialized using an annular model. A non-rigid image-registration technique is then used to assess myocardial deformation. Three experiments were set up to validate the proposed framework using a clinical database of 75 patients. First, automatic segmentation accuracy was evaluated by comparing against manual delineations at one specific cardiac phase. The proposed solution showed an average perpendicular distance error of 2.35 +/- 1.21 mm and 2.27 +/- 1.02 mm for the endo- and epicardium, respectively. Second, starting from either manual or automatic segmentation, myocardial tracking was performed and the resulting strain curves were compared. It is shown that the automatic segmentation adds negligible differences during the strain-estimation stage, corroborating its accuracy. Finally, segmental strain was compared with scar tissue extent determined by delay-enhanced MRI. The results proved that both strain components were able to distinguish between normal and infarct regions. Overall, the proposed framework was shown to be accurate, robust, and attractive for clinical practice, as it overcomes several limitations of a manual analysis.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

tagged magnetic resonance imaging; fully automatic segmentation; non-rigid image registration; strain estimation

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Morais, Pedro
Queiros, Sandro
Heyde, Brecht
Engvall, Jan
Dhooge, Jan
Vilaca, Joao L.
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Image Pr ...
Articles in the publication
Physics in Medic ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view