An experimental investigation of the flow and comfort parameters for under-floor, confluent jets and mixing ventilation systems in an open-plan office

Arghand, Taha (author)
Högskolan i Gävle,Energisystem,Chalmers tekniska högskola,Chalmers University of Technology
Karimipanah, Taghi, 1953- (author)
Högskolan i Gävle,Energisystem
Awbi, Hazim, 1946- (author)
School of Construction Management and Engineering, University of Reading, United Kingdom
show more...
Cehlin, Mathias, 1974- (author)
Högskolan i Gävle,Energisystem
Larsson, Ulf, 1966- (author)
Högskolan i Gävle,Energisystem
Linden, Elisabet (author)
Högskolan i Gävle,BMG-labbet
show less...
 (creator_code:org_t)
Elsevier BV, 2015
2015
English.
In: Building and Environment. - : Elsevier BV. - 0360-1323 .- 1873-684X. ; 92, s. 48-60
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • There is a new trend to convert the workplaces from individual office rooms to open offices for motivating money saving and better communication. With such a shift the ability of existing ventilation systems in meeting the new requirements is a challenging question for researchers. The available options could have an impact on workers' health in terms of providing acceptable levels of thermalcomfort and indoor air quality. Thus, this experimental investigation focuses on the performances of three different air distribution systems in an open-plan office space. The investigated systems were: mixing ventilation with ceiling-mounted inlets, confluent jets ventilation and underfloor air distribution with straight and curved vanes. Although this represents a small part of our more extensiveexperimental investigation, the results show that all the purposed stratified ventilation systems (CJV and UFAD) were more or less behaving as mixing systems with some tendency for displacement effects. Nevertheless, it is known that the mixing systems have a stable flow pattern but has the disadvantage of mixing contaminated air with the fresh supplied air which may produce lower performance and in worst cases occupants' illness. For the open-plan office we studied here, it will be shown that the new systems are capable of performing better than the conventional mixing systems. As expected, the higher air exchange efficiency in combination with lower local mean age of air for corner-mounted CJV and floor-mounted UFAD grills systems indicates that these systems are suitable for open-plan offices and are to be favored over conventional mixing systems.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

Open office
Mixing ventilation (MV)
Underfloor air distribution (UFAD)
Confluent jets ventilation (CJV)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view