Predictors of rate-...
Predictors of rate-adaptive pacing in patients implanted with implantable cardioverter-defibrillator and subsequent differential clinical outcomes
-
- Källner, Nils (author)
- Region Östergötland
-
- Nishimura, Marin (author)
- Univ Calif San Diego, CA 92037 USA
-
- Birgersdotter-Green, Ulrika (author)
- Univ Calif San Diego, CA 92037 USA
-
show more...
-
- Hoffmayer, Kurt S. (author)
- Univ Calif San Diego, CA 92037 USA
-
- Han, Frederick T. (author)
- Univ Calif San Diego, CA 92037 USA
-
- Krummen, David E. (author)
- Univ Calif San Diego, CA 92037 USA
-
- Raissi, Farshad (author)
- Univ Calif San Diego, CA 92037 USA
-
- Feld, Gregory K. (author)
- Univ Calif San Diego, CA 92037 USA
-
- Hsu, Jonathan C. (author)
- Univ Calif San Diego, CA 92037 USA
-
show less...
-
(creator_code:org_t)
- 2019-03-30
- 2019
- English.
-
In: Journal of Interventional Cardiac Electrophysiology. - : SPRINGER. - 1383-875X .- 1572-8595. ; 55:1, s. 83-91
- Related links:
-
https://urn.kb.se/re...
-
show more...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- PurposePatients with severe cardiomyopathy often have chronotropic incompetence, which is predominantly managed by activating rate-adaptive pacing in patients implanted with an implantable cardioverter-defibrillator (ICD) capable of atrial pacing. The purpose of this study was to determine predictors of rate-adaptive pacing activation, the cumulative incidence of activation, and the association of rate-adaptive pacing activation with subsequent clinical outcomes in an ICD population.MethodsThe authors evaluated 228 patients implanted with an ICD between 2011 and 2015. Multivariable logistic regression was used to evaluate predictors of rate-adaptive pacing activation. Cox proportional-hazards regression was used to examine associations of rate-adaptive pacing activation and clinical outcomes.ResultsRate-adaptive pacing was turned on in 38.5% (n=88) of patients during follow-up. Several statistically significant predictors of rate-adaptive pacing activation were found, particularly previous atrial fibrillation (odds ratio [OR]=8.27, 95% confidence interval [CI]=2.96-23.06, pamp;lt;0.001), previous myocardial infarction (OR=4.17, 95% CI=1.38-12.58, p=0.01), and non-ischemic cardiomyopathy (OR=3.83, 95% CI=1.22-12.00, p=0.02). In multivariable adjusted analyses, rate-adaptive pacing activation within 30days of implantation was not associated with the risk of device therapy for tachyarrhythmias (hazard ratio [HR]=1.52, 95% CI=0.71-3.28, p=0.29), atrial fibrillation (HR=1.42, 95% CI=0.71-2.87, p=0.32), HF re-admission (HR=1.39, 95% CI=0.80-2.43, p=0.25), nor all-cause mortality (HR=2.34, 95% CI=0.80-6.84, p=0.12).ConclusionsDuring follow-up, more than one in three HF patients implanted with an ICD developed the need for rate-adaptive pacing. Atrial fibrillation, prior myocardial infarction, and non-ischemic cardiomyopathy were statistically significant baseline clinical predictors of rate-adaptive pacing activation. Rate-adaptive pacing activation was not associated with subsequent adverse clinical outcomes.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Keyword
- Cardiac resynchronization therapy; Cardiomyopathy; Chronotropic incompetence; Implantable cardioverter-defibrillator; Rate-adaptive pacing; Sick sinus syndrome