SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-161391"
 

Search: onr:"swepub:oai:DiVA.org:liu-161391" > A comparison of sta...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A comparison of stability of chemical analytes in plasma from the BD Vacutainer (R) Barricor (TM) tube with mechanical separator versus tubes containing gel separator

Gawria, Ghassaan (author)
Linköpings universitet,Avdelningen för klinisk kemi,Medicinska fakulteten,Region Östergötland, Klinisk kemi
Tillmar, Linda, 1974- (author)
Linköpings universitet,Avdelningen för klinisk kemi,Medicinska fakulteten,Region Östergötland, Klinisk kemi
Landberg, Eva, 1966- (author)
Linköpings universitet,Avdelningen för cellbiologi,Medicinska fakulteten,Region Östergötland, Klinisk kemi
 (creator_code:org_t)
2019-10-11
2020
English.
In: Journal of clinical laboratory analysis (Print). - : WILEY. - 0887-8013 .- 1098-2825. ; 34:2
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: There is a need of prolonged stability of certain chemical analytes in lithium heparin tubes with separators. A new tube with a mechanical separator has recently been launched (Barricor (TM)), which according to the manufacturer may have these benefits. The aim of this study was to evaluate stability performance of this tube in comparison with plasma gel tubes under clinically realistic circumstances. Methods: Blood was collected in tubes containing lithium heparin with different separators; gel separator (Vacutainer (R) PST (TM), Becton Dickinson and Vacuette (R), Greiner bio-one) and mechanical separator (Vacutainer (R) Barricor (TM), Becton Dickinson). All tubes had an aspiration volume of 3 mL and were centrifuged at similar time and force. Tubes were transported manually or by car. Seven analytes from 122 patients were analyzed after 3 to 80 hours by Cobas c701 (Roche). Results The Barricor (TM) tube showed increased stability of phosphate and potassium and similar stability of aspartate aminotransferase, glucose, homocysteine, lactate dehydrogenase, and magnesium compared with gel tubes. Maximal allowable bias for phosphate was exceeded after 68 hours for Barricor (TM) tubes compared with 29 or 35 hours for gel tubes and for potassium after 40 hours for Barricor (TM) tubes vs 9 or 12 hours for gel tubes. Transportation did not affect stability. Hemolysis index was slightly lower in Barricor tubes than in gel tubes (P = .01). Conclusion Implementing the new Barricor (TM) tube will improve stability of potassium and phosphate in plasma. Blood sampling facilities far from the laboratory may benefit from using these tubes, thus diminishing preanalytical errors.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Läkemedelskemi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Medicinal Chemistry (hsv//eng)

Keyword

phosphate; plasma; potassium; separator; stability; tube

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Gawria, Ghassaan
Tillmar, Linda, ...
Landberg, Eva, 1 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Basic Medicine
and Medicinal Chemis ...
Articles in the publication
Journal of clini ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view