Quantitative Assessment and Repeatability of Chlorine in Exhaled Breath Condensate : Comparison of Two Types of Condensators

Davidsson, Anette, 1960- (author)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken
Naidu-Sjöswärd, Kerstin (author)
Östergötlands Läns Landsting,Linköpings universitet,Anestesiologi med intensivvård,Hälsouniversitetet,Intensivvårdskliniken US
Lundman, Lena (author)
Linköpings universitet,Tema vatten i natur och samhälle,Filosofiska fakulteten
show more...
Schmekel, Birgitta (author)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken
show less...
 (creator_code:org_t)
2005-09-16
2005
English.
In: Respiration. - : S. Karger AG. - 0025-7931 .- 1423-0356. ; 72:5, s. 529-536
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Airway condition is presumably reflected in epithelial lining fluid (ELF). Exhaled breath condensate (EBC) has been used as a surrogate marker of the composition of ELF. Objectives: This study aimed at assessing the technical repeatability of chlorine measurements in EBC and comparing two separate condensators (Ecoscreen® and R Tube™) regarding recovery and repeatability. Furthermore, the association between condensate recoveries and variations in the airway status were scrutinized. Methods: EBC was collected using two condensators from 10 healthy volunteers. In addition, 13 asthmatic patients produced EBC with or without an added resistance of 5 cm H2O (Res5), applied to the outflow tract of Ecoscreen. All tests were done in random order. Chlorine levels (analyzed by a coulometric technique) in EBC served as a tool for investigation. Results: Chlorine was measurable in all samples. The coefficient of repeatability of chlorine measurements was <10%. Chlorine levels were higher in EBC obtained from R Tube (p < 0.001), and differences in recoveries and variability in chlorine levels were presumably related to technical differences in the condensators and not to the repeatability of chlorine measurements per se. Air-flow-dependent chlorine levels were obtained from healthy volunteers. Application of Res5, recruiting additional alveoli, resulted in increased recovery of the EBC volume, but not of chlorine, from those that had the most pronounced airway obstruction (p = 0.05). Conclusion: We conclude that by employing a sensitive analysis technique, chlorine is repeatedly measurable in EBC. We suggest that the bulk of chlorine in EBC originates from large airways and not from the alveolar area. Both condensators were comparable regarding repeatability but differed regarding chlorine recover

Keyword

Asthma
Chlorine
Exhaled breath condensate
Repeatability
Volunteers
MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view