SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-169365"
 

Search: onr:"swepub:oai:DiVA.org:liu-169365" > Standardized Measur...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Standardized Measurement of Capillary Refill Time using Novel Technology

Junker, Johan, 1980- (author)
Linköpings universitet,Avdelningen för Kirurgi, Ortopedi och Onkologi,Medicinska fakulteten,Region Östergötland, Katastrofmedicinskt centrum
Jonson, Carl-Oscar, Docent, 1978- (author)
Linköpings universitet,Avdelningen för Kirurgi, Ortopedi och Onkologi,Medicinska fakulteten,Region Östergötland, Katastrofmedicinskt centrum
Henricson, Joakim, 1977- (author)
Linköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, Akutkliniken i Linköping
 (creator_code:org_t)
Cambridge University Press, 2019
2019
English.
In: Prehospital and Disaster Medicine. - : Cambridge University Press. - 1049-023X .- 1945-1938. ; 34:s1, s. 167-168
  • Journal article (other academic/artistic)
Abstract Subject headings
Close  
  • Introduction: In a patient going into shock, blood is redistributed from the periphery to the central circulation, making an assessment of skin perfusion useful in a prehospital setting. Capillary refill time (CRT) is the time required for a pressure blanched skin site to reperfuse. Currently, CRT is tested by manually applying pressure for 5s to the skin and observing the time before reperfusion. Guidelines state that CRT should be 2-3s in a healthy patient. Shortcomings in this procedure include lack of standardization of pressure, subjective assessment of the time for reperfusion, and not accounting for the patient’s skin temperature.Aim: To develop a standardized objective procedure for testing CRT in the prehospital setting.Method: The study protocol was approved by the Ethics Committee at Linköping University (M200-07, 2015-99-31). An electro-pneumatic device exerting constant force (9N) over 5s was developed. CRT was measured using the Tissue Viability Imager (Wheelsbridge AB, Sweden) which relies on polarization spectroscopy. To simulate hypothermic conditions, healthy volunteers were subjected to low ambient temperature (8°C). Blood loss was simulated using a custom-built lower body negative pressure (LBNP) chamber. In both scenarios, the CRT test was carried out on three test sites (finger pulp, forehead, and sternum).Results: CRT on the finger pulp and sternum was shown to be increased following the hypothermic conditions, but not on the forehead. Skin temperature on the three sites followed the same pattern, with the forehead being virtually unchanged. Tests performed during LBNP revealed an apparent effect on CRT following the simulated blood loss, with prolonged CRT for all sites tested.Discussion: A successful methodology for objective assessment of CRT was developed, which was validated on healthy volunteers following hypothermia or simulated blood loss. Ongoing work will investigate a combination of hypothermia and blood loss to more accurately simulate the prehospital setting.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Publication and Content Type

vet (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Junker, Johan, 1 ...
Jonson, Carl-Osc ...
Henricson, Joaki ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Basic Medicine
and Physiology
Articles in the publication
Prehospital and ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view