SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-169997"
 

Search: onr:"swepub:oai:DiVA.org:liu-169997" > Experimental assess...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Experimental assessment of a phosphor model for estimating the relative extrinsic efficiency in radioluminescent detectors

Lindstrom, Jan (author)
Karolinska Univ Hosp, Sweden
Alm Carlsson, Gudrun (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik
Wahlin, Erik (author)
Karolinska Univ Hosp, Sweden
show more...
Carlsson Tedgren, Åsa (author)
Karolinska Institutet,Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik,Karolinska Univ Hosp, Sweden
Poludniowski, Gavin (author)
Karolinska Institutet,Karolinska Univ Hosp, Sweden
show less...
 (creator_code:org_t)
Elsevier, 2020
2020
English.
In: Physica medica (Testo stampato). - : Elsevier. - 1120-1797 .- 1724-191X. ; 76, s. 117-124
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Optimising phosphor screens in dose detectors or imaging sensor designs is a cumbersome and time- consuming work normally involving specialised measuring equipment and advanced modelling. It is known that crucial optical parameters of the same phosphor may vary within a wide range of values. The aim of this work was to experimentally assess a simple previously published model where the case specific optical parameters (scattering and absorption) are instead represented by a fixed, single parameter, the light extinction factor, xi. The term extrinsic efficiency, N, of a phosphor is also introduced, differing from the common denotation "absolute efficiency", after noting that unknown factors (such as temperature dependence) can have an influence during efficiency estimations and hence difficult to claim absoluteness. N is expressed as the ratio of light energy emitted per unit area at the phosphor surface to incident x-ray energy fluence. By focusing on ratios and relative changes in this study, readily available instruments in a Medical Physics Department (i.e. a photometer) could be used. The varying relative extrinsic efficiency for an extended range of particle sizes (7.5 and 25 mu m) and layer thicknesses (220 to 830 mu m) were calculated in the model from the input parameters: the mean particle size of the phosphor, the layer thickness, the light extinction factor and the calculated energy imparted to the layer. In-house manufactured screens (Gd2O2S:Tb) were used for better control of design parameters. The model provided good qualitative agreement to experiment with quantitative deviations in relative extrinsic efficiency within approximately 2%.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Energy transport; Extrinsic efficiency; Fluorescence; Optimisation; Phosphor model; Radioluminescence

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view