SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-175071"
 

Search: onr:"swepub:oai:DiVA.org:liu-175071" > On the Consequences...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

On the Consequences of Poorly Defined Breakpoints for Rifampin Susceptibility Testing of Mycobacterium tuberculosis Complex

Koser, Claudio U. (author)
Univ Cambridge, England
Georghiou, Sophia B. (author)
FIND, Switzerland
Schön, Thomas (author)
Linköpings universitet,Avdelningen för inflammation och infektion,Medicinska fakulteten,Region Östergötland, Infektionskliniken i Östergötland,Department of Infectious Diseases, Kalmar County Hospital,Sweden
show more...
Salfinger, Max (author)
Univ S Florida, FL 33620 USA; Univ S Florida, FL 33620 USA
show less...
 (creator_code:org_t)
AMER SOC MICROBIOLOGY, 2021
2021
English.
In: Journal of Clinical Microbiology. - : AMER SOC MICROBIOLOGY. - 0095-1137 .- 1098-660X. ; 59:4
  • Journal article (other academic/artistic)
Abstract Subject headings
Close  
  • In a recent report of a systematic review of critical concentrations (CCs), the World Health Organization (WHO) lowered the rifampin (RIF) CC for antimicrobial susceptibility testing (AST) of the Mycobacterium tuberculosis complex using Middlebrook 7H10 medium and the Bactec Mycobacterial Growth Indicator Tube (MGIT) 960 system from 1 to 0.5mg/ ml. The previous RIF CC for 7H10 had been in use for over half a century. Because it had served as the de facto reference standard, it contributed to the endorsement of inappropriately high CCs for other AST methods, including the U.S. Food and Drug Administration (FDA)-approved MGIT system. Moreover, this resulted in confusion about the interpretation of seven borderline resistance mutations in rpoB (i.e., L430P, D435Y, H445L, H445N, H445S, L452P, and I491F). In this issue of the Journal of Clinical Microbiology, Shea et al. (J Clin Microbiol 59:e01885-20, 2021, https://doi.org/10.1128/JCM.01885-20) provide evidence that the CC endorsed by the Clinical and Laboratory Standards Institute for the Sensititre MYCOTB system, which is not FDA approved but is CE-IVD marked in the European Union, is likely also too high. These findings underscore the importance of calibrating AST methods against a rigorously defined reference standard, as recently proposed by the European Committee on Antimicrobial Susceptibility Testing, as well as the value of routine next-generation sequencing for investigating discordant AST results.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Infektionsmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Infectious Medicine (hsv//eng)

Publication and Content Type

vet (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Koser, Claudio U ...
Georghiou, Sophi ...
Schön, Thomas
Salfinger, Max
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Infectious Medic ...
Articles in the publication
Journal of Clini ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view