Sökning: onr:"swepub:oai:DiVA.org:liu-180002" >
Robotic TAMIS: A Te...
Robotic TAMIS: A Technical Note Comparing Si (R) versus Xi (R)
-
- Kajmolli, Agon (författare)
- Westchester Med Ctr, NY 10595 USA
-
- Javadov, Mirkhalig (författare)
- Yeditepe Univ Hosp, Turkey
-
- Felsenreich, Daniel Moritz (författare)
- Med Univ Vienna, Austria
-
visa fler...
-
- Popa, Dorin (författare)
- Region Östergötland, Kirurgiska kliniken US
-
- Bergamaschi, Roberto (författare)
- New York Med Coll, NY 10595 USA; Westchester Med Ctr, NY USA
-
visa färre...
-
(creator_code:org_t)
- SURGICAL TECHNOLOGY INT ONLINE, 2021
- 2021
- Engelska.
-
Ingår i: SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH. - : SURGICAL TECHNOLOGY INT ONLINE. - 1090-3941. ; 38
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.5...
-
visa färre...
Abstract
Ämnesord
Stäng
- Transanal minimally invasive surgery (TAMIS) can be performed robotically assisted (R-TAMIS) for easier rectal defect suture closure particularly on the anterior rectal wall. The surgical technique described in this technical note emphasizes three safety points: 1) decreased likelihood for rectal injury when the ports are inserted into the GelPOINT (R) Path Transanal Access Platform (Applied Medical, Rancho Santa Margarita, California) on the back table rather than being inserted into the rectum; 2) decreased external collision between ports when using ports of different length; and 3) increased stabilization of pneumorectum when insufflating with an AirSeal (TM) port (Intelligent Flow System, ConMed, Utica, New York). Although R-TAMIS can be safely performed with the da Vinci (R) Si (R) or Xi (R) (Intuitive Surgical Inc., Sunnyvale, California) patient cart, the following differences are noteworthy: a) the Si (R) vertically-mounted arms design forces the patient in an uncomfortable position with asymmetrical hip flexion as opposed to the Xi (R) boom-mounted horizontal arm design; b) the 28cm circumference of each Si (R) patient cart arms operating between the patients legs offer decreased maneuvering freedom as opposed to the 19cm circumference of the Xi (R) counterparts; and c) the abduction pattern of movement of the Si (R) arms potentially increases the risk of external collision with the patients legs as opposed to the Xi (R) "jack-knife" pattern of movement.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas