SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-184568"
 

Search: onr:"swepub:oai:DiVA.org:liu-184568" > FluoRa - a System f...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Klint, ElisabethLinköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten (author)

FluoRa - a System for Combined Fluorescence and Microcirculation Measurements in Brain Tumor Surgery

  • Article/chapterEnglish2021

Publisher, publication year, extent ...

  • IEEE,2021
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-184568
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-184568URI
  • https://doi.org/10.1109/EMBC46164.2021.9629801DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:kon swepub-publicationtype

Notes

  • Funding Agencies|Swedish Foundation for Strategic ResearchSwedish Foundation for Strategic Research [RMX18-0056]
  • In brain tumor surgery it is difficult to distinguish the marginal zone with the naked eye. Fluorescence techniques can help identifying tumor tissue in the zone during resection and biopsy procedures. In this paper a novel system for combined real-time measurements of PpIX-fluorescence, microcirculation and tissue grey-whiteness is presented and experimentally evaluated. The system consists of a fluorescence hardware with a sensitive CCD spectrometer for PpIX peak detection, a laser Doppler system, optical probes, and a LabView software. System evaluation was done on static fluorescing material, human skin, and brain tumor tissue. The static material indicates reproducibility, the skin measurements exemplify simultaneous fluorescence and microcirculation measurement in real-time, and the tumor tissue showed PpIX peaks. These decreased over time, as expected, due to photo bleaching. In addition, the system was prepared for clinical use and thus laser- and electrical safety issues were considered. In summary, a system for multiparameter measurements during neurosurgery was successfully evaluated in an experimental environment. As a next step the system will be applied in clinical brain tumor biopsies and resections.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Mauritzon, StinaLinköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten(Swepub:liu)stima53 (author)
  • Ragnemalm, BengtLinköpings universitet,Centrum för social och affektiv neurovetenskap,Medicinska fakulteten(Swepub:liu)benra10 (author)
  • Richter, JohanLinköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,Region Östergötland, Neurokirurgiska kliniken US(Swepub:liu)johri42 (author)
  • Wårdell, KarinLinköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten(Swepub:liu)karwa46 (author)
  • Linköpings universitetAvdelningen för medicinsk teknik (creator_code:org_t)

Related titles

  • In:2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC): IEEE, s. 1512-15159781728111797

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Klint, Elisabeth
Mauritzon, Stina
Ragnemalm, Bengt
Richter, Johan
Wårdell, Karin
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
2021 43RD ANNUAL ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view