SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-187292"
 

Search: onr:"swepub:oai:DiVA.org:liu-187292" > Assessment of image...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Kämmerling, NinaLinköpings universitet,Institutionen för hälsa, medicin och vård,Medicinska fakulteten,Region Östergötland, Röntgenkliniken i Linköping (author)

Assessment of image quality in photon-counting detector computed tomography of the wrist - An ex vivo study

  • Article/chapterEnglish2022

Publisher, publication year, extent ...

  • Elsevier Ireland Ltd,2022
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-187292
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-187292URI
  • https://doi.org/10.1016/j.ejrad.2022.110442DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Funding Agencies|ALF Grants [RO?]
  • Purpose: The aim of this study was to evaluate the effect of reconstruction parameters on image quality in wrist imaging using photon-counting detector CT (PCD-CT) and to compare the results with images from an energyintegrating detector CT (EID-CT). Methods: Twelve cadaveric wrist specimens were examined using a prototype PCD-CT and a clinical EID-CT using similar radiation dose. Reconstruction parameters were matched between scanners. Also, sharper reconstruction kernels, a larger matrix size, and smaller slice thicknesses were evaluated for PCD-CT. Image noise, contrast-tonoise ratio (CNR) and image sharpness in trabecular structures were quantitatively measured. Image quality with respect to the visibility of cortical and trabecular bone structures was assessed by six radiologists using visual grading methods.Results: Images obtained with PCD-CT had lower noise (42.6 +/- 3.9 HU vs 75.1 +/- 6.3 HU), higher CNR (38.9 +/- 4.5 vs 19.0 +/- 2.4) and higher trabecular sharpness (63.5 +/- 6.0 vs 53.7 +/- 8.5) than those obtained with EID-CT using similar scan and reconstruction parameters (p < 0.001). The image sharpness in trabecular structures was further improved by using sharper kernels, despite higher noise levels. Radiologists had a strong preference for PCD-CT images both in terms of spatial resolution and suitability for bone imaging. Visual grading analysis showed an improved visibility of cortical bone, trabeculae and nutritive canals (p < 0.005).Conclusion: PCD-CT offers improved image quality regarding bone structures in the wrist relative to EID-CT systems, particularly when sharper reconstruction kernels, smaller slice thickness and a larger image matrix size are used.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Sandstedt, MårtenLinköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping(Swepub:liu)marsa80 (author)
  • Farnebo, SimonLinköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US(Swepub:liu)simfa69 (author)
  • Persson, AndersLinköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping(Swepub:liu)andpe75 (author)
  • Tesselaar, ErikLinköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik(Swepub:liu)eridr03 (author)
  • Linköpings universitetInstitutionen för hälsa, medicin och vård (creator_code:org_t)

Related titles

  • In:European Journal of Radiology: Elsevier Ireland Ltd1540720-048X1872-7727

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view