SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-193601"
 

Search: onr:"swepub:oai:DiVA.org:liu-193601" > Performance specifi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Performance specifications for sodium should not be based on biological variation

Oosterhuis, Wytze P. (author)
EFLM Task & Finish Grp Pract Approach Measurement, Italy; Reinier Haga Med Diagnost Ctr, Netherlands; Reinier Graafweg 7, Netherlands
Coskun, Abdurrahman (author)
EFLM Task & Finish Grp Pract Approach Measurement, Italy; Istanbul Univ, Turkey
Sandberg, Sverre (author)
EFLM Task & Finish Grp Pract Approach Measurement, Italy; Haraldsplass Diaconess Hosp, Norway; Univ Bergen, Norway
show more...
Theodorsson, Elvar (author)
Linköpings universitet,Avdelningen för klinisk kemi och farmakologi,Medicinska fakulteten,Region Östergötland, Klinisk kemi,EFLM Task & Finish Grp Pract Approach Measurement, Italy
show less...
 (creator_code:org_t)
ELSEVIER, 2023
2023
English.
In: Clinica Chimica Acta. - : ELSEVIER. - 0009-8981 .- 1873-3492. ; 540
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • When increasing the quality in clinical laboratories by decreasing measurement uncertainty, reliable methods are needed not only to quantify the performance of measuring systems, but also to set goals for the performance. Sigma metrics used in medical laboratories for documenting and expressing levels of performance, are evidently totally dependent on the "total permissible error" used in the formulas. Although the conventional biological variation (BV) based model for calculation of the permissible (or allowable) total error is commonly used, it has been shown to be flawed. Alternative methods are proposed, mainly also based on the within-subject BV. Measurement uncertainty models might offer an alternative to total error models. Defining the limits for analytical quality still poses a challenge in both models. The aim of the present paper is to critically discuss current methods for establishing performance specifica-tions by using the measurement of sodium concentrations in plasma or serum. Sodium can be measured with high accuracy but fails by far to meet conventional performance specifications based on BV. Since the use of sodium concentrations is well established for supporting clinical care, we question the concept that quality criteria for sodium and similar analytes that are under strict homeostatic control are best set by biology.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

Biological variation; Number of distinct categories; Six Sigma; Sigma metric; Total error; Analytical performance specification

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Oosterhuis, Wytz ...
Coskun, Abdurrah ...
Sandberg, Sverre
Theodorsson, Elv ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
Clinica Chimica ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view