Microcirculatory response to cold stress test in the healthy hand

Detert, Hedvig (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US
Karlernäs, Astrid (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US
Rubensson, Carin (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US
show more...
Nyman, Erika (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US
Tesselaar, Erik (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik
Farnebo, Simon (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US
show less...
 (creator_code:org_t)
ACADEMIC PRESS INC ELSEVIER SCIENCE, 2023
2023
English.
In: Microvascular Research. - : ACADEMIC PRESS INC ELSEVIER SCIENCE. - 0026-2862 .- 1095-9319. ; 148
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: Cold sensitivity of the fingers is common in several conditions. It has been linked to digital vasospasm, microvascular dysfunction, and neural mechanisms. This study aimed to investigate the normal digital micro-vascular response to a cold stress test in healthy individuals using Laser Speckle Contrast Imaging (LSCI).Methods: Twenty-six healthy individuals, mean age 31 (SD 9) years were included. Skin perfusion of digits II-V was measured using Laser Speckle Contrast Imaging before and after a standardized cold stress test. Changes in skin perfusion from baseline were analyzed between hands, digits, and sexes.Results: Skin perfusion was significantly (p < 0.0001) affected by cold provocation in both the cold exposed and the contralateral hands in all participants of the study. This effect was significantly different between the radial (digit II and III) and the ulnar (digit V) side of the hands (p < 0.001). There was a trend towards a larger decrease in perfusion in men (ns), and a faster recovery to baseline values in women (ns). A larger inter subject variability was seen in perfusion values in women.Conclusions: The normal microvascular response to cold provocation may involve both centrally and regionally mediated processes. When exposing one hand to a cold stress test, the contralateral hand responds with simul-taneous but smaller decreases in perfusion.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

Cold intolerance; Cold stress test; Microcirculation; Perfusion

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view