SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-29493"
 

Search: onr:"swepub:oai:DiVA.org:liu-29493" > On the measurement ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

On the measurement of evaporative water loss : methods and clinical applications

Nilsson, Gert, 1947- (author)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,Onkologi,Hälsouniversitetet
 (creator_code:org_t)
ISBN 917372131X
Linköping : Zäta Tryckerierna, 1977
English 42 s.
Series: Linköping Studies in Science and Technology. Dissertations, 0345-7524 ; 11
Series: Linköping University Medical Dissertations, 0345-0082 ; 48
  • Doctoral thesis (other academic/artistic)
Abstract Subject headings
Close  
  • The new method for measurement of water loss by evaporation from the skin described in paper I, offers a high degree of accuracy and improved sensitivity in comparison with devices reported previously. Rapid recordings can be made by technically untrained persons both in clinical departments and in the laboratory.Using this method, the average insensible perspiration from the skin of healthy adult subjects at rest was found to be 381, 526 and 695 gr per day at ambient temperatures of 22°, 27° and 30°C, respectively. On the head, hands and feet the evaporation rate was high, while on other body surface areas more moderate values were recorded,In a clinical study on newborn infants, a linear relationship between the evaporative water loss from the skin and the ambient humidity was found. At an ambient temperature of 34.5°c and an ambient relative humidity of 50% the average transepidermal water loss was calculated to be 8.1 g/m2h.In burned patients high evaporation rates from about 140 g/m2h to over 220 g/m2h were recorded on the injured skin surfaces. Biological dressings were only slightly permeable to water vapour, while the permeability of the artificial dressings tested was generally high.By recording the rate of increase in vapour concentration in a closed measurement chamber placed over the exposed abdominal cavity during surgery, the water loss by evaporation from wounds and exteriorized viscera was determined. At incisions of minor extent the evaporative water loss was low, while at larger incisions with exteriorized viscera the water loss by evaporation from the wound exceeded the basal cutaneous perspiration of healthy adult subjects.

Keyword

MEDICINE
MEDICIN

Publication and Content Type

vet (subject category)
dok (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view