SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-32562"
 

Search: onr:"swepub:oai:DiVA.org:liu-32562" > Evaluation of Enhan...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Lindén, Maria,1965-Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet (author)

Evaluation of Enhanced High-Resolution Laser Doppler Imaging in an in Vitro Tube Model with the Aim of Assessing Blood Flow in Separate Microvessels

  • Article/chapterEnglish1998

Publisher, publication year, extent ...

  • Elsevier BV,1998
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-32562
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-32562URI
  • https://doi.org/10.1006/mvre.1998.2095DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • An enhanced high-resolution laser Doppler imaging (EHR-LDI) technique intended for visualization of separate microvessels was evaluated by use ofin vitroflow models. In EHR-LDI, a laser beam focused to a half-power diameter less than 40 μm successively scans the tissue under study in steps of 25 μm. Spatial blood flow variations within microvascular structures of 1.5 × 1.5 mm are rendered by 64 × 64 measurement sites. Individual microvessel diameters could be estimated and an average difference of 11 μm compared to microscopic measurements was obtained. For the flow algorithm used, the LDI output signal was found to scale linearly with average velocity (0–3.5 mm/s) when a plastic tube of inner diameter 175 μm was perfused with human blood (correlation coefficient 0.99). The LDI output signal was further found insensitive to hematocrit variations in the range 16–44%. Due to the limited laser light penetration in blood, a reduction in the LDI output signal was observed as the inner tube diameters were successively changed from 280 to 1400 μm.

Subject headings and genre

  • MEDICINE
  • MEDICIN

Added entries (persons, corporate bodies, meetings, titles ...)

  • Golster, HelenaLinköpings universitet,Hand och plastikkirurgi,Anestesiologi med intensivvård,Hälsouniversitetet (author)
  • Bertuglia, SilviaCNR Institute of Clinical Physiology, Via Trieste, Pisa, Italy (author)
  • Colantuoni, AntonioCNR Institute of Clinical Physiology, Via Trieste, Pisa, Italy (author)
  • Sjöberg, Folke,1956-Linköpings universitet,Hand och plastikkirurgi,Anestesiologi med intensivvård,Hälsouniversitetet(Swepub:liu)folsj94 (author)
  • Nilsson, Gert,1947-Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet(Swepub:liu)gerni17 (author)
  • Linköpings universitetInstitutionen för medicinsk teknik (creator_code:org_t)

Related titles

  • In:Microvascular Research: Elsevier BV56:3, s. 261-2700026-28621095-9319

Internet link

Find in a library

To the university's database