SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-32562"
 

Search: onr:"swepub:oai:DiVA.org:liu-32562" > Evaluation of Enhan...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00002898naa a2200337 4500
001oai:DiVA.org:liu-32562
003SwePub
008091009s1998 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-325622 URI
024a https://doi.org/10.1006/mvre.1998.20952 DOI
040 a (SwePub)liu
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Lindén, Maria,d 1965-u Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet4 aut
2451 0a Evaluation of Enhanced High-Resolution Laser Doppler Imaging in an in Vitro Tube Model with the Aim of Assessing Blood Flow in Separate Microvessels
264 1b Elsevier BV,c 1998
338 a print2 rdacarrier
520 a An enhanced high-resolution laser Doppler imaging (EHR-LDI) technique intended for visualization of separate microvessels was evaluated by use ofin vitroflow models. In EHR-LDI, a laser beam focused to a half-power diameter less than 40 μm successively scans the tissue under study in steps of 25 μm. Spatial blood flow variations within microvascular structures of 1.5 × 1.5 mm are rendered by 64 × 64 measurement sites. Individual microvessel diameters could be estimated and an average difference of 11 μm compared to microscopic measurements was obtained. For the flow algorithm used, the LDI output signal was found to scale linearly with average velocity (0–3.5 mm/s) when a plastic tube of inner diameter 175 μm was perfused with human blood (correlation coefficient 0.99). The LDI output signal was further found insensitive to hematocrit variations in the range 16–44%. Due to the limited laser light penetration in blood, a reduction in the LDI output signal was observed as the inner tube diameters were successively changed from 280 to 1400 μm.
653 a MEDICINE
653 a MEDICIN
700a Golster, Helenau Linköpings universitet,Hand och plastikkirurgi,Anestesiologi med intensivvård,Hälsouniversitetet4 aut
700a Bertuglia, Silviau CNR Institute of Clinical Physiology, Via Trieste, Pisa, Italy4 aut
700a Colantuoni, Antoniou CNR Institute of Clinical Physiology, Via Trieste, Pisa, Italy4 aut
700a Sjöberg, Folke,d 1956-u Linköpings universitet,Hand och plastikkirurgi,Anestesiologi med intensivvård,Hälsouniversitetet4 aut0 (Swepub:liu)folsj94
700a Nilsson, Gert,d 1947-u Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet4 aut0 (Swepub:liu)gerni17
710a Linköpings universitetb Institutionen för medicinsk teknik4 org
773t Microvascular Researchd : Elsevier BVg 56:3, s. 261-270q 56:3<261-270x 0026-2862x 1095-9319
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-32562
8564 8u https://doi.org/10.1006/mvre.1998.2095

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view