SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-46443"
 

Search: onr:"swepub:oai:DiVA.org:liu-46443" > Accuracy and reprod...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Accuracy and reproducibility in phase contrast imaging using SENSE

Thunberg, Per (author)
Linköpings universitet,Institutionen för medicinsk teknik,Klinisk fysiologi,Hälsouniversitetet,Department of Biomedical Engineering, Örebro University Hospital, Örebro, Sweden; Department of Biomedical Engineering, Linköping University, Linköping, Sweden; 3Department of Medicine and Care, Division of Clinical Physiology, Linköping University, Linköping, Sweden
Karlsson, Matts (author)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,Department of Biomedical Engineering, Linköping University, Linköping, Sweden
Wigström, Lars (author)
Linköpings universitet,Institutionen för medicinsk teknik,Klinisk fysiologi,Hälsouniversitetet,2Department of Biomedical Engineering, Linköping University, Linköping, Sweden; 3Department of Medicine and Care, Division of Clinical Physiology, Linköping University, Linköping, Sweden
 (creator_code:org_t)
2003-10-24
2003
English.
In: Magnetic Resonance in Medicine. - Hoboken, USA : Wiley. - 0740-3194 .- 1522-2594. ; 50:5, s. 1061-1068
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The purpose of this study was to evaluate the accuracy and reproducibility of phase contrast imaging using the sensitivity encoding (SENSE) method at different reduction factors. Analytical expressions were derived that state how reproducibility is influenced for velocity and flow measurements. Computer simulations, and in vitro and in vivo studies were performed in order to validate these expressions and to assess how accuracy is affected when different reduction factors are applied. It was shown that reproducibility depends on the reduction and geometry factors. Since the geometry factor varies spatially, so does the reproducibility for phase contrast imaging. In areas with high geometry factors, the standard deviation (SD) may become so large that aliasing occurs. The accuracy of phase contrast imaging is not influenced directly when SENSE is used, but may be indirectly influenced due to high SDs of the measured phase that may subsequently cause aliasing. The current results show that it is possible to achieve accurate flow measurements even at high reduction factors. By taking the geometry factor into account, it may be possible to find areas where phase contrast imaging is accurate even at high reduction factors.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Flow quantification
Parallel MRI
Phase contrast imaging
Reproducibility
SENSE
MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Thunberg, Per
Karlsson, Matts
Wigström, Lars
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Magnetic Resonan ...
By the university
Linköping University
Örebro University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view