SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-47548"
 

Search: onr:"swepub:oai:DiVA.org:liu-47548" > Sensitivity deviati...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Sensitivity deviation : Instrumental linearity errors that influence concentration analyses and kinetic evaluation of biomolecular interactions

Johansen, Knut (author)
Linköpings universitet,Tekniska högskolan,Institutionen för fysik, kemi och biologi
Lundström, Ingemar (author)
Linköpings universitet,Tekniska högskolan,Tillämpad Fysik
Liedberg, Bo (author)
Linköpings universitet,Tekniska högskolan,Sensorvetenskap och Molekylfysik
 (creator_code:org_t)
2000
2000
English.
In: Biosensors & bioelectronics. - 0956-5663 .- 1873-4235. ; 15:9-10, s. 503-509
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Many scientific instruments utilise multiple element detectors, e.g. CCD's or photodiode arrays, to monitor the change in a position of an optical pattern. For example, instruments for affinity biosensing based on surface plasmon resonance (SPR) or resonant mirror are equipped with such detectors. An important and desired property of these bioanalytical instruments is that the calculation of the movement or change in shape follows the true change. This is often not the case and it may lead to linearity errors, and to sensitivity errors. The sensitivity is normally defined as the slope of the calibration curve. A new parameter is introduced to account for the linearity errors, the sensitivity deviation, defined as the deviation from the undistorted slope of the calibration curve. The linearity error and the sensitivity deviation are intimately related and the sensitivity deviation may lead to misinterpretation of kinetic data, mass transport limitations and concentration analyses. Because the linearity errors are small (e.g. 10 pg/mm2 of biomolecules on the sensor surface) with regard to the dynamic range (e.g. 30 000 pg/mm2), they can be difficult to discover. However, the linearity errors are often not negligible with regard to a typical response (e.g. 0-100 pg/mm2), and may therefore cause serious problems. A method for detecting linearity errors is outlined. Further on, this paper demonstrates how integral linearity errors of less than 1% can result in a sensitivity deviation of 10%, a value that in our opinion cannot be ignored in biospecific interaction analysis (BIA). It should also be stressed out that this phenomenon also occurs in other instruments using array detectors. (C) 2000 Elsevier Science S.A.Many scientific instruments utilize multiple element detectors, e.g. CCD's or photodiode arrays, to monitor the change in a position of an optical pattern. For example, instruments for affinity biosensing based on surface plasmon resonance (SPR) or resonant mirror are equipped with such detectors. An important and desired property of these bioanalytical instruments is that the calculation of the movement or change in shape follows the true change. This is often not the case and it may lead to linearity errors, and to sensitivity errors. The sensitivity is normally defined as the slope of the calibration curve. A new parameter is introduced to account for the linearity errors, the sensitivity deviation, defined as the deviation from the undistorted slope of the calibration curve. The linearity error and the sensitivity deviation are intimately related and the sensitivity deviation may lead to misinterpretation of kinetic data, mass transport limitations and concentration analyses. Because the linearity errors are small (e.g. 10 pg/mm2 of biomolecules on the sensor surface) with regard to the dynamic range (e.g. 30 000 pg/mm2), they can be difficult to discover. However, the linearity errors are often not negligible with regard to a typical response (e.g. 0-100 pg/mm2), and may therefore cause serious problems. A method for detecting linearity errors is outlined. Further on, this paper demonstrates how integral linearity errors of less than 1% can result in a sensitivity deviation of 10%, a value that in our opinion cannot be ignored in biospecific interaction analysis (BIA). It should also be stressed out that this phenomenon also occurs in other instruments using array detectors.

Keyword

TECHNOLOGY
TEKNIKVETENSKAP

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Johansen, Knut
Lundström, Ingem ...
Liedberg, Bo
Articles in the publication
Biosensors & bio ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view