Search: onr:"swepub:oai:DiVA.org:liu-66090" >
A spectroscopic app...
A spectroscopic approach to imaging and quantification of cartilage lesions in human knee joints
-
- Johansson, Anders (author)
- Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,BioOptico AB, Teknikringen 10, 583 30 Linköping, Sweden
-
- Sundqvist, Tommy (author)
- Linköpings universitet,Hälsouniversitetet,Medicinsk mikrobiologi
-
- Kuiper, J.-H. (author)
- Keele University School of Medicine, Keele, UK,The Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, UK
-
show more...
-
- Öberg, Åke (author)
- Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
-
show less...
-
(creator_code:org_t)
- 2011-03-01
- 2011
- English.
-
In: Physics in Medicine and Biology. - : IOP. - 0031-9155 .- 1361-6560. ; 56:6, s. 1865-1878
- Related links:
-
https://urn.kb.se/re...
-
show more...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- We have previously described a technology based on diffuse reflectance of broadband light for measuring joint articular cartilage thickness, utilizing that optical absorption is different in cartilage and subchondral bone. This study is the first evaluation of the technology in human material. We also investigated the prospects of cartilage lesion imaging, with the specific aim of arthroscopic integration. Cartilage thickness was studied ex vivo in a number of sites (n = 87) on human knee joint condyles, removed from nine patients during total knee replacement surgery. A reflectance spectrum was taken at each site and the cartilage thickness was estimated using the blue, green, red and near-infrared regions of the spectrum, respectively. Estimated values were compared with reference cartilage thickness values (taken after sample slicing) using an exponential model. Two-dimensional Monte Carlo simulations were performed in a theoretical analysis of the experimental results. The reference cartilage thickness of the investigated sites was 1.60 ± 1.30 mm (mean ± SD) in the range 0–4.2 mm. Highest correlation coefficients were seen for the calculations based on the near-infrared region after normalization to the red region (r = 0.86) and for the green region (r = 0.80).
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
Keyword
- Medical engineering
- Medicinsk teknik
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database