Diffuse reflectance spectroscopy: Systemic and microvascular oxygen saturation is linearly correlated and hypoxia leads to increased spatial heterogeneity of microvascular saturation

Awan, Z A (author)
Oslo University Hospital
Häggblad, Erik (author)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
Wester, T (author)
Oslo University Hospital
show more...
Kvernebo, M S (author)
Oslo University Hospital,
Halvorsen, P S (author)
Oslo University Hospital
Kvernebo, K (author)
Oslo University Hospital
show less...
 (creator_code:org_t)
Elsevier Science B.V., Amsterdam, 2011
2011
English.
In: MICROVASCULAR RESEARCH. - : Elsevier Science B.V., Amsterdam. - 0026-2862. ; 81:3, s. 245-251
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The microvascular oxygen saturation (SmvO(2)) in the skin and tongue (sublingual mucosa) in pigs (n = 6) was characterised using diffuse reflectance spectroscopy (DRS). The correlation between arterial oxygen saturation (SaO(2)) and SmvO(2) as well as the spatial heterogeneity of SmvO(2) was examined during hypoxia. DRS uses shallow-penetrating visible light to assess microvascular oxygen saturation (SmvO(2)) in superficial tissue. Hypoxia was induced by gradual reduction in ventilation or reduction of the inspiratory oxygen fraction. The spatial heterogeneity of SmvO(2) was expressed as the coefficient of variation (CV) of repeated SmvO(2) measurements. Baseline SmvO(2) before interventions was 20.2% (10.3%-38.1%, median with range) in groin skin, 32.9% (13.0%-49.3%) in the ear and 42.2% (32.1%-51.5%) in the tongue. SmvO(2) in the groin was significantly lower than venous oxygen saturation (SvO(2)) (p andlt; 0.05) and SmvO(2) in the tongue (p = 0.03). There was a significant linear correlation between SaO(2) and SmvO(2) in all measuring sites for both interventions (pandlt;0.05). Similarly there was a significant correlation between CV of repeated SmvO(2) measurements and SmvO(2) in all measuring sites for both interventions (p andlt; 0.01). The results from baseline measurements indicate a surprisingly high oxygen extraction in the measurement volume of DRS, especially in the groin skin. A reduction of SmvO(2) with decreasing SaO(2) was found and additionally the results suggest that spatial heterogeneity of microvascular oxygen saturation increases during hypoxia. Microvascular disturbances have been demonstrated in both local vascular diseases and systemic conditions such as shock and sepsis, an assessment of microvascular oxygen saturation using DRS may be useful in the monitoring of the microcirculation in such patients. This study is a part of an ongoing characterization of the DRS technique.

Keyword

Diffuse reflectance spectroscopy
Hypoxia
Hypoxemia
Microvascular oxygenation
Skin microcirculation
Sublingual microcirculation
Method characteristics
Bedside measurement
Non-invasive
TECHNOLOGY
TEKNIKVETENSKAP

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view