The Kudo humeral component as primary hemiarthroplasty in distal humeral fractures

Adolfsson, Lars (author)
Östergötlands Läns Landsting,Linköpings universitet,Ortopedi och idrottsmedicin,Hälsouniversitetet,Ortopedkliniken i Linköping
Nestorson, Jens (author)
Östergötlands Läns Landsting,Ortopedkliniken Linköping
 (creator_code:org_t)
Elsevier, 2012
2012
English.
In: Journal of shoulder and elbow surgery. - : Elsevier. - 1058-2746 .- 1532-6500. ; 21:4, s. 451-455
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Treatment of intra-articular fractures of the distal humerus in the elderly is challenging. In patients with very distal fractures and severe comminution, primary arthroplasty has been advocated. Recently, a few reports have described promising results of hemiarthroplasty. This study describes the medium-term results of using the Kudo humeral implant (Biomet Ltd, Bridgend, U. K.) as replacement of the distal humerus. less thanbrgreater than less thanbrgreater thanMaterial and methods: Eight women (mean age, 79 years) were treated. Follow-up was conducted at a mean of 4 years after the procedure and consisted of the Mayo Elbow Performance Score (MEPS), radiographic images, and range of motion (ROM). less thanbrgreater than less thanbrgreater thanResults: All patients had a good or excellent outcome according to the MEPS. Mean ROM was 31 degrees to 126 degrees. Radiographic signs of attrition of the ulna were observed in 3 patients but did not correlate with the functional outcome. A periprosthetic fracture occurred in 1 patient 3 years after the index operation, and ROM was unsatisfactory in 1 patient. No other complications were observed. less thanbrgreater than less thanbrgreater thanConclusion: The use of the Kudo humeral implant as a hemiarthroplasty resulted in a reasonable functional outcome in the medium-term, but the radiographic signs of attrition suggest that the implant is not recommended as a hemiprosthesis.

Keyword

Distal humeral fracture
osteoporosis
Kudo prosthesis
elderly women
elbow hemiarthroplasty
radiographic attrition
MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Adolfsson, Lars
Nestorson, Jens
Articles in the publication
Journal of shoul ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view