Radiation dose optimization in coronary angiography and percutaneous coronary intervention (PCI) : I. Experimental studies

Geijer, Håkan (author)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
Beckman, Karl-Wilhelm (author)
Department of Medical Physics, Örebro University Hospital, Örebro, Sweden
Andersson, Torbjörn (author)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
show more...
Persliden, Jan (author)
Department of Medical Physics, Örebro University Hospital, Örebro, Sweden
show less...
 (creator_code:org_t)
2002-01-26
2002
English.
In: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 12:10, s. 2571-2581
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The objectives of this study were to evaluate the influence on image quality and dose to the patient and operator of various equipment settings for percutaneous coronary intervention (PCI), and to optimize the set-up. With an Alderson phantom, different settings, such as projection, protective screens, filtration, image intensifier size and collimation, were evaluated. Kerma-area product (KAP) was recorded as a measure of patient dose and scattered radiation was measured with an ionization chamber. Effective dose for a standardized PCI procedure was measured with thermoluminescent dosimeters inside the phantom. Image quality was evaluated with a contrast-detail phantom. Based on these findings, the equipment set-up was optimized to a low fluoroscopy dose rate with a sufficient image quality. Several operating parameters affected dose, particularly scattered radiation. The optimization reduced the fluoroscopy KAP rate from 44 to 16 mGy cm2/s using 15 cm of acrylic. The effective dose was reduced from 13 to 4.6 mSv for a standardized PCI procedure. Radiation dose to patient and operator in PCI is heavily dependent on both equipment set-up and operating parameters which can be influenced by the operator. With a careful optimization, a large reduction of radiation dose is possible.

Keyword

MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view