SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-90019"
 

Search: onr:"swepub:oai:DiVA.org:liu-90019" > Patient dose and im...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Kataria, BhartiÖstergötlands Läns Landsting,Linköpings universitet,Institutionen för medicin och hälsa,Medicinska fakulteten,Närsjukvården i östra Östergötland (author)

Patient dose and image quality in low-dose abdominal CT : a comparison between iterative reconstruction and filtered back projection

  • Article/chapterEnglish2013

Publisher, publication year, extent ...

  • 2013-06-01
  • SAGE Publications,2013
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-90019
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-90019URI
  • https://doi.org/10.1177/0284185113476019DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Background In computed tomography (CT), there is increasing concern for potential CT radiation hazards. Several raw-data-based iterative reconstruction techniques attempt to facilitate low-dose imaging without compromising image quality, which raises the question whether these techniques may allow further dose reduction.Purpose To compare image quality of iterative reconstruction and filtered back projection in low-dose abdominal CT and study the potential for further dose reduction.Material and Methods Forty-five patients underwent CT of the abdomen twice: with standard low-dose technique and with 30% reduced dose, using both iterative reconstruction and filtered back projection. Four radiologists made pair-wise image quality assessment using five visual criteria. Visual grading regression (VGR) and weighted kappa (κ w) were used to analyze the data.Results There were significant effects of log(mAs) (P <0.001) and reconstruction algorithm (P <0.01) on all image quality criteria with an estimated potential dose reduction of 5–9%. Inter-observer agreement ranged from 70% to 91% and κ w from −0.01 to 0.57.Conclusion An iterative reconstruction algorithm improved image quality in abdominal CT, but the estimated dose reduction was rather small. The full potential of the algorithm remains unclear.

Added entries (persons, corporate bodies, meetings, titles ...)

  • Smedby, ÖrjanÖstergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping(Swepub:liu)orjsm14 (author)
  • Linköpings universitetInstitutionen för medicin och hälsa (creator_code:org_t)

Related titles

  • In:Acta Radiologica: SAGE Publications54:5, s. 540-5480284-18511600-0455

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Kataria, Bharti
Smedby, Örjan
Articles in the publication
Acta Radiologica
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view