Search: onr:"swepub:oai:DiVA.org:lnu-106039" >
Reduction in the in...
Reduction in the incidence of awareness using BIS monitoring
-
- Ekman, Andreas (author)
- Regional hospital, Sweden;Karolinska Institute, Sweden
-
- Lindholm, L.-M. (author)
- Regional hospital, Sweden;Karolinska Institute, Sweden
-
- Lennmarken, Claes, 1948- (author)
- Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Anestesiologi,Intensivvårdskliniken US
-
show more...
-
- Sandin, R. (author)
- Karolinska Institutet
-
show less...
-
(creator_code:org_t)
- 2003-12-12
- 2004
- English.
-
In: Acta Anaesthesiologica Scandinavica. - : John Wiley & Sons. - 0001-5172 .- 1399-6576. ; 48, s. 20-26
- Related links:
-
https://urn.kb.se/re...
-
show more...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
http://kipublication...
-
show less...
Abstract
Subject headings
Close
- Reduction in the incidence of awareness using BISmonitoringA. EKMAN1,M-L.LINDHOLM1,C.LENNMARKEN2and R. SANDIN11Department of Anaesthesia and Intensive Care, Regional hospital, Kalmar, and The Karolinska Institute, Stockholm, and2Department ofAnaesthesia and Intensive Care, University Hospital, Linko¨ping, SwedenBackground: Explicit recall (ER) is evident i n a pproximat ely0.2% of patients given general anaesthesia including musclerelaxants. This prospective study was performed to evaluate ifcerebral monitoring using BIS to guide the conduction ofanaesthesia could reduce this incidence significantly.Patients and methods: A prospective cohort of 4945 consecutivesurgical patients requiring muscle relaxants and/or intubationwere monitored with BIS and subsequently interviewed for ERon three occasions. BIS values between 40 and 60 were recom-mended. The results from the BIS-monitored group of patientswas compared with a historical group of 7826 similar cases in aprevious study when no cerebral monitoring was used.Results: Two patients in th e BIS-monitored grou p, 0 .0 4% ,hadER as c ompared with 0.18% in the control group (P < 0.038).Both BIS-monitored patients with ER were aware during intub-ation when they had high BIS values (>60) for 4 min andmore than 10 min, respectively. However, periods with high BIS ¼ 4 min were al so eviden t in other patient s with no ER .Episodes with high BIS, 4 min or more, were found in 19% ofthe monitored patients during induction, and in 8% of casesduring maintenance.Conclusions: The use of BIS monitoring during general anaes-thesia requiring endotracheal intubation and/or muscle relax-ants was associated with a significantly reduced incidence ofawareness as compared with a historical control population.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
Keyword
- Anaesthesia Awareness
- Brain function monitoring
- BIS
- Medicin
- Medicine
- MEDICINE
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database