SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:lnu-117348"
 

Search: onr:"swepub:oai:DiVA.org:lnu-117348" > Evaluation of incre...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Evaluation of increased electricity production when cooling solar panels

Rupar-Gadd, Katarina, 1974- (author)
Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET),SBER
Truong, Nguyen Le, 1976- (author)
Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET)
Mahapatra, Krushna, Professor, 1974- (author)
Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET)
 (creator_code:org_t)
Bristol, United Kingdom : Institute of Physics (IOP), 2022
2022
English.
In: SBE22Delft - Innovations for the Urban Energy Transition. - Bristol, United Kingdom : Institute of Physics (IOP).
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • A municipal housing company located in the south of Sweden has energy renovatedseveral buildings with a total of 380 apartments to meet today’s energy standards. Several energyefficient technologies and solutions were implemented and the energy consumption for thesebuildings were lowered by 50%. One of the buildings functions as a demonstration building forinnovative solutions such as low temperature district heating, waste water heat recovery, andsolar photovoltaic and thermal (PVT) panels. The solar PVT panels are cooled down with themain purpose to increase the electricity production. The cooling medium for these panels iscirculated through two bedrock boreholes to dissipate the collected heat. The heat from theboreholes is then used for an electric heat pump to produce heat to send to the local districtheating company. The electricity produced is primarily used in the building. The objective ofthis paper is to assess the electricity production from real-life outdoor Photovoltaic-thermal(PVT) plant. The plant was installed on the roof top of an energy renovated multi-familyapartment building located in the south of Sweden. The cooling of the panels were turned on andoff to assess if the electricity production would increase or not. The electricity production didnot increase when the cooling was applied. The temperature measuring equipment which wasinstalled at the wrong position and was supposed to measure the temperature at the back of thePVT is needed to compare the efficiency of the PVT plant and draw further conclusions.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Keyword

PVT
multi family buildings
solar panels
energy coordinator
solar energy
smart energy system solution
Technology (byts ev till Engineering)
Teknik
Sustainable Built Environment
Hållbar byggd miljö

Publication and Content Type

ref (subject category)
kon (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Rupar-Gadd, Kata ...
Truong, Nguyen L ...
Mahapatra, Krush ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Environmental En ...
and Energy Systems
Articles in the publication
By the university
Linnaeus University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view