SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:lnu-21192"
 

Search: onr:"swepub:oai:DiVA.org:lnu-21192" > Model calibration o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Model calibration of locally nonlinear structures using information from sub and super harmonic responses

Chen, Yousheng, 1985- (author)
Linnéuniversitetet,Institutionen för teknik, TEK,Maskinteknik
Yaghoubi Nasrabadi, Vahid, 1985 (author)
Chalmers,Strukturdynamik,Chalmers tekniska högskola,Chalmers University of Technology
Linderholt, Andreas, 1968- (author)
Linnéuniversitetet,Institutionen för teknik, TEK,Maskinteknik
show more...
Abrahamsson, Thomas, 1956 (author)
Chalmers,Strukturdynamik,Chalmers tekniska högskola,Chalmers University of Technology
show less...
 (creator_code:org_t)
ISBN 9781622768257
Leuven : Katholieke Universiteit Leuven, Department of Mechanical Engineering, 2012
2012
English.
In: International Conference on Noise and Vibration Engineering 2012 (ISMA 2012). - Leuven : Katholieke Universiteit Leuven, Department of Mechanical Engineering. - 9781622768257 ; , s. 2451-2464
  • Conference paper (other academic/artistic)
Abstract Subject headings
Close  
  • Large linear finite element models are commonly used in industry to represent global structural behavior and such models are often validated by use of data from vibrational tests. The validated models serve to predict the structural responses due to dynamic loads. Hence, it is important to have models that are able to represent the structural dynamics within the given operating envelope. When test data show proof of non linear behavior, a linear model may not be able to represent the dynamics well enough and thus a modification of the model is required. The main part of the structure may have a linear characteristic whereas localized physical processes can be sources of the observed nonlinearities. Model calibration of such locally nonlinear structures is studied in this paper. Specifically, the calibration process including the selection of appropriate data to be used for calibration of the model parameters chosen is treated. Here, synthetic test data stemming from a model of the Ecole Centrale de Lyon (ECL) nonlinear benchmark are used.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Rymd- och flygteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Aerospace Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Keyword

Nonlinear
Structural dynamics
Mechanical Engineering
Maskinteknik

Publication and Content Type

vet (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view