SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:lnu-38159"
 

Search: onr:"swepub:oai:DiVA.org:lnu-38159" > Model Calibration o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Model Calibration of a Locally Non-linear Structure Utilizing Multi Harmonic Response Data

Chen, Yousheng, 1985- (author)
Linnéuniversitetet,Institutionen för maskinteknik (MT),Maskinteknik
Yaghoubi Nasrabadi, Vahid, 1985 (author)
Chalmers University of Technology,Chalmers tekniska högskola
Linderholt, Andreas (author)
Linnéuniversitetet,Institutionen för maskinteknik (MT),Maskinteknik
show more...
Abrahamsson, Thomas, 1956 (author)
Chalmers University of Technology,Strukturdynamik,Chalmers tekniska högskola
show less...
 (creator_code:org_t)
ISBN 9783319045214
2014-03-11
2014
English.
In: Nonlinear Dynamics, Volume 2. - Cham : Springer. - 2191-5644 .- 2191-5652. - 9783319045221 - 9783319045214 ; , s. 97-109
  • Conference paper (peer-reviewed)
Table of contents Abstract Subject headings
Close  
No table of content available
  • Model correlation and model calibration using test data are natural ingredients in the process of validating computational models. Here, model calibration for the important sub-class of non-linear systems consisting of structures dominated by linear behavior having presence of local non-linear effects is studied. The focus is on the selection of uncertain model parameters together with the forming of the objective function to be used for calibration. To give precise estimation of parameters in the presence of measurement noise, the objective function data have to be informative with respect to the parameters chosen. Also, to get useful data the excitation force is here designed to be multi-harmonic since steady-state responses at the side frequencies are shown to contain valuable information for the calibration process. In this paper, test data from a replica of the Ecole Centrale de Lyon (ECL) nonlinear benchmark together with steady-state solutions stemming from calculations using the Multi-Harmonic Balancing method are used for illustration of the proposed model calibration procedure.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Keyword

Nonlinear
Multi-harmonic
Identifiability
Fisher information matrix
Calibration
Mechanical Engineering
Maskinteknik

Publication and Content Type

ref (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view