Experimental Validation of a Nonlinear Model Calibration Method Based on Multiharmonic Frequency Responses

Chen, Yousheng, 1985- (author)
Linnéuniversitetet,Institutionen för maskinteknik (MT),Strukturdynamik
Linderholt, Andreas, 1968- (author)
Linnéuniversitetet,Institutionen för maskinteknik (MT),Strukturdynamik
Abrahamsson, Thomas, 1956 (author)
Chalmers University of Technology,Strukturdynamik,Chalmers tekniska högskola
 (creator_code:org_t)
2017-02-01
2017
English.
In: Journal of Computational and Nonlinear Dynamics. - : ASME Press. - 1555-1415 .- 1555-1423. ; 12:4
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Correlation and calibration using test data are natural ingredients in the process of validating computational models. Model calibration for the important subclass of nonlinear systems which consists of structures dominated by linear behavior with the presence of local nonlinear effects is studied in this work. The experimental validation of a nonlinear model calibration method is conducted using a replica of the École Centrale de Lyon (ECL) nonlinear benchmark test setup. The calibration method is based on the selection of uncertain model parameters and the data that form the calibration metric together with an efficient optimization routine. The parameterization is chosen so that the expected covariances of the parameter estimates are made small. To obtain informative data, the excitation force is designed to be multisinusoidal and the resulting steady-state multiharmonic frequency response data are measured. To shorten the optimization time, plausible starting seed candidates are selected using the Latin hypercube sampling method. The candidate parameter set giving the smallest deviation to the test data is used as a starting point for an iterative search for a calibration solution. The model calibration is conducted by minimizing the deviations between the measured steady-state multiharmonic frequency response data and the analytical counterparts that are calculated using the multiharmonic balance method. The resulting calibrated model's output corresponds well with the measured responses.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Teknisk mekanik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Applied Mechanics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Keyword

nonlinear model calibration
multiharmonic frequency response
identifiability analysis
Fisher information matrix
Maskinteknik
Mechanical Engineering

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view