Search: onr:"swepub:oai:DiVA.org:lnu-71797" >
Contrast sensitivit...
-
Lewis, Peter,1971-Linnéuniversitetet,Institutionen för medicin och optometri (MEO),Linnaeus Univ, Dept Med & Optometry, Kalmar, Sweden.
(author)
Contrast sensitivity in eyes with central scotoma : effect of stimulus drift
- Article/chapterEnglish2018
Publisher, publication year, extent ...
-
Wolters Kluwer,2018
-
printrdacarrier
Numbers
-
LIBRIS-ID:oai:DiVA.org:lnu-71797
-
https://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-71797URI
-
https://doi.org/10.1097/OPX.0000000000001195DOI
-
https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-228286URI
Supplementary language notes
-
Language:English
-
Summary in:English
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
This research was also supported by “Berit and Carl-Johan Wettergrens Foundation.”
-
QC 20180521
-
SignificanceIn the field of visual rehabilitation of patients with central visual field loss, knowledge on how peripheral visual function can be improved is essential. This study presents measurements of peripheral dynamic contrast sensitivity (with optical correction) for off-axis viewing angles in subjects with central visual field loss.PurposeSubjects with central visual field loss (CFL) rely on a peripheral preferred retinal locus (PRL) for many visual tasks. It is therefore important to ascertain that contrast sensitivity (CS) is maximized in the PRL. This study evaluates the effect of stimulus motion, in combination with optical correction, on CS in subjects with CFL.MethodsThe off-axis refractive errors in the PRL of five young CFL subjects were measured with a COAS open-view Hartmann-Shack aberrometer. Low-contrast (25% and 10%) and high-contrast resolution acuity for stationary gratings was assessed with and without optical correction. High-contrast resolution was also measured for gratings drifting at 7.5 Hz (within a fixed Gaussian window). Furthermore, resolution CS was evaluated for both stationary and moving gratings with optical correction for a total of 2-3 spatial frequencies per subject.ResultsHigh-contrast resolution acuity was relatively insensitive to stimulus drift motion of 7.5 Hz, whereas CS for gratings of 0.5 cycles per degree improved with drift for all subjects. Furthermore, both high- and low-contrast static resolution improved with optical correction.Conclusions Just as for heathy eyes, stimulus motion of 7.5 Hz enhances CS for gratings of low spatial frequency also in the PRL of eyes with CFL. Concurrently, high contrast resolution is unaffected by the 7.5 Hz drift, but improves with off-axis optical correction. This highlights the importance of providing optimal refractive correction for subjects with CFL, and that stimulus motion can be used to further enhance CS at low spatial frequencies.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Venkataraman, Abinaya Priya,1985-KTH,Tillämpad fysik,KTH Royal institute of technology, Sweden(Swepub:kth)u19ndov7
(author)
-
Lundström, LindaKTH,Tillämpad fysik,KTH Royal institute of technology, Sweden(Swepub:kth)u1j0at99
(author)
-
LinnéuniversitetetInstitutionen för medicin och optometri (MEO)
(creator_code:org_t)
Related titles
-
In:Optometry and Vision Science: Wolters Kluwer95:4, s. 354-3611040-54881538-9235
Internet link
Find in a library
To the university's database