Search: onr:"swepub:oai:DiVA.org:ltu-14505" >
Laboratory study of...
Laboratory study of infiltration into two frozen engineered (sandy) soils recommended for bioretention
-
- Moghadas, Shahab (author)
- Luleå tekniska universitet,Arkitektur och vatten
-
- Perttu, Anna-Maria (author)
- Luleå tekniska universitet,Arkitektur och vatten
-
- Viklander, Peter (author)
- Luleå tekniska universitet,Geoteknologi
-
show more...
-
- Marsalek, Jiri (author)
- Luleå tekniska universitet,Arkitektur och vatten
-
- Viklander, Maria (author)
- Luleå tekniska universitet,Arkitektur och vatten
-
show less...
-
(creator_code:org_t)
- 2015-11-21
- 2016
- English.
-
In: Hydrological Processes. - : Wiley. - 0885-6087 .- 1099-1085. ; 30:8, s. 1251-1264
- Related links:
-
https://urn.kb.se/re...
-
show more...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Infiltration of water into two frozen engineered soils of different gradation was studied in laboratory soil columns 1.2 m long and 0.1 m in diameter. Prior to testing, the soil moisture was adjusted to two levels, described by the gravimetric water content of 5 or 10%, soils were compacted to about 80-90% of the maximum dry density, and refrigerated to temperatures ranging from −8 to −2 °C. Water with temperatures 8-9 °C was thereafter fed on the top of columns at a constant head and the times of water break through the column and reaching a steady percolation rate, as well as the percolation rate, were recorded. The soil water content was a critical factor affecting the thawing process; during freezing, soil moisture was converted into ice, which blocked pores, and its melting required high amounts of energy supplied by infiltrating water. Hence, the thawing of soils with higher initial water content was much slower than in lower moisture soils, and water breakthrough and the attainment of steady percolation required much longer times in higher moisture soils. Heat transfer between infiltrating water, soil ice and frozen soil particles was well described by the energy budget equations, which constitute a parsimonious model of the observed processes. The finer grained soil and more compacted soil columns exhibited reduced porosity and required longer times for soil thawing. Practical implications of study results for design of bioretention facilities (BFs) in cold climate include the use of coarse engineered soils and fitting BFs with a drain facilitating soil drainage before the onset of freezing weather. This article is protected by copyright. All rights reserved.
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Water Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Geoteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Geotechnical Engineering (hsv//eng)
Keyword
- VA-teknik
- Urban Water Engineering
- Soil Mechanics
- Geoteknik
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database