Bolted shear connectors vs. headed studs behaviour in push-out tests

Pavlović, Marko (author)
Faculty of Civil Engineering, University of Belgrade
Marković, Zlatko (author)
Faculty of Civil Engineering, University of Belgrade
Veljkovic, Milan (author)
Luleå tekniska universitet,Byggkonstruktion och -produktion
show more...
Buđevac, Dragan (author)
Faculty of Civil Engineering, University of Belgrade
show less...
 (creator_code:org_t)
Elsevier BV, 2013
2013
English.
In: Journal of constructional steel research. - : Elsevier BV. - 0143-974X .- 1873-5983. ; 88, s. 134-149
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Prefabrication of concrete slabs reduces construction time for composite steel–concrete buildings and bridges. Different alternatives for shear connectors (bolts and headed studs) are analysed here to gain better insight in failure modes of shear connector in order to improve competiveness of prefabricated composite structures. Casting of high strength bolted shear connectors in prefabricated concrete slabs offers the higher level of prefabrication comparing to a standard method of grouting welded headed studs in envisaged pockets of concrete slabs. In addition, bolted shear connectors can easily be dismantled together with the concrete slab thus allowing the improved sustainability of the construction, simpler maintenance, and development of modular structural systems. Bolted shear connectors have been rarely used in construction, actually just for rehabilitation works, because there is a lack of design recommendation. The first step towards the design recommendation is to understand the difference between the headed shear studs and the bolted shear connectors in a push-out test. Push-out tests, according to EN1994-1-1, using 4 M16 — grade 8.8 bolts with embedded nut in the same layout and test set-up as for previously investigated headed studs were performed. Finite element models for both shear connectors were created, and good match with experimental data was obtained. Basic shear connector properties such as: shear resistance, stiffness, ductility and failure modes have been compared and discussed in detail by using experimental and FE results. Parametric FE analyses of shear connector's height are carried out and shear resistance reduction factor has been proposed for bolted shear connectors.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

Steel Structures
Stålbyggnad

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Pavlović, Marko
Marković, Zlatko
Veljkovic, Milan
Buđevac, Dragan
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Building Technol ...
Articles in the publication
Journal of const ...
By the university
Luleå University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view