SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:ltu-95147"
 

Sökning: onr:"swepub:oai:DiVA.org:ltu-95147" > Noise Level in Text...

Noise Level in Textile Industries: Case Study Al-Hillah Textile Factory-Company for Textile Industries, Al-Hillah-Babylon-Iraq

Chabuk, Ali (författare)
University of Babylon, College of Engineering, Department of Environment Engineering, Babylon 51001, Iraq
Hammood, Zahraa Ali (författare)
Al-Mustaqbal University College, Research and Studies Unit, 51001 Hillah, Babil, Iraq
Abed, Salwan Ali (författare)
University of Al-Qadisiyah, College of Science, Department of Environment, P.O. Box.1895, Iraq
visa fler...
Kadhim, Majid M.A. (författare)
University of Babylon, College of Engineering, Department of Architecture Engineering, Babylon 51001, Iraq
Hashim, Khalid (författare)
University of Babylon, College of Engineering, Department of Environment Engineering, Babylon 51001, Iraq
Al-Ansari, Nadhir (författare)
Luleå tekniska universitet,Geoteknologi
Laue, Jan (författare)
Luleå tekniska universitet,Geoteknologi
visa färre...
 (creator_code:org_t)
Institute of Physics (IOP), 2021
2021
Engelska.
Ingår i: First International Virtual Conference on Environment & Natural Resources. - : Institute of Physics (IOP).
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study, Al-Hillah Textile Factory, in Al-Hillah city-Iraq follows to State Company for Textile Industries was selected to study the intensity of noise in 2014. Measurements of the noise level were carried out in different workshops for each of the production stages including the spinning machinery workshop (parts 1 and 2), the rotating machinery room, the preparations room, and the textile machinery room (Roti model), weaving machines: Techmash model room Russian-made model room, Sheets' machinery room, and operator machines room; using two noise meters (model 2237 Fulfici). Fifty samples were collected in each part of these rooms to give realistic results for the noise level. After recording the noise level data, the highest and lowest values and the average of noise intensity readings were calculated in each of the rooms and compared with the global standards permitted by the EPA for industrial facilities. The results of this study showed that the general rate of noise intensity in all rooms exceeded the permissible limits, which impose a noise level of 65-70dB for such industrial establishments according to EPA recommendations in 2008.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)

Nyckelord

Al-Hillah Textile Factory
Al-Hillah-Babylon- Iraq
Industrial
Noise
Textile Factory
Machines
Soil Mechanics
Geoteknik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy