SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:mau-15492"
 

Search: onr:"swepub:oai:DiVA.org:mau-15492" > Volumetric measurem...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Volumetric measurement of dentoalveolar defects by means of intraoral 3D scanner and gravimetric model

Lindström, Martin J R (author)
Malmö universitet,Odontologiska fakulteten (OD)
Ahmad, Marianne (author)
Malmö universitet,Odontologiska fakulteten (OD)
Jimbo, Ryo (author)
Malmö universitet,Odontologiska fakulteten (OD)
show more...
Ameri, Arman (author)
Malmö universitet,Odontologiska fakulteten (OD)
Vult von Steyern, Per (author)
Malmö universitet,Odontologiska fakulteten (OD)
Becktor, Jonas P (author)
Malmö universitet,Odontologiska fakulteten (OD)
show less...
 (creator_code:org_t)
2019-01-07
2019
English.
In: Odontology. - : Springer. - 1618-1247 .- 1618-1255. ; 103:3, s. 353-359
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The aim of this study was to evaluate the accuracy in volumetric measurements obtained on an experimental model using an intraoral scanner and a gravimetric method. Three identical partial dentate maxillary acrylic models with three fabricated alveolar defects, in anterior and posterior regions, were scanned using an intraoral scanner (20 scans/defects). The defects differed in terms of size and distance of neighbouring teeth. As references, replicas of each defect were created using a dimensional stable silicone impression material. After measuring the mass of each replica, the volume was calculated by dividing the mass of each replica by the density of the impression material. The defects had a volume, according to the gravimetric method, ranging from 40.5 to 143.7 mm. The scans were imported to metrology software for analyses. Accuracy was determined in terms of trueness and precision. The mean trueness for all defect types was 0.168 mm (SD 0.691, range 2.82). There was no statistical significant difference between the mean trueness for all defects measured (p = 0.910). The mean precision for all defect types was 0.147 mm (SD 0.524, range 2.86). There were no statistical significant differences between the dental models in regard to mean precision (p = 0.401), however, there were statistical significant differences between defects in position 1 and 2 (p = 0.002) and 1 and 3 (p = 0.001). Based on the findings of this study, the intraoral scanner utilized in the current study presented an acceptable level of accuracy when measuring volume of defects.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

Intraoral scanning
Surgical techniques
Tissue alterations
Volumetric measurement
Wound healing

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Odontology (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Lindström, Marti ...
Ahmad, Marianne
Jimbo, Ryo
Ameri, Arman
Vult von Steyern ...
Becktor, Jonas P
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Odontology
By the university
Malmö University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view