Implant Stability and Bone Remodeling after 3 and 13 Days of Implantation with an Initial Static Strain

Halldin, Anders (author)
Malmö högskola,Odontologiska fakulteten (OD)
Jimbo, Ryo (author)
Malmö högskola,Odontologiska fakulteten (OD)
Johansson, Carina B., 1955 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
show more...
Wennerberg, Ann (author)
Malmö högskola,Odontologiska fakulteten (OD)
Jacobsson, Magnus (author)
Malmö högskola,Odontologiska fakulteten (OD)
Albrektsson, Tomas (author)
Gothenburg University,Göteborgs universitet,Malmö högskola,Odontologiska fakulteten (OD),Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Hansson, Stig (author)
show less...
 (creator_code:org_t)
2012-10-15
2014
English.
In: Clinical Implant Dentistry and Related Research. - : John Wiley & Sons. - 1523-0899 .- 1708-8208. ; 16:3, s. 383-393
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective Bone is constantly exposed to dynamic and static loads, which induce both dynamic and static bone strains. Although numerous studies exist on the effect of dynamic strain on implant stability and bone remodeling, the effect of static strain needs further investigation. Therefore, the effect of two different static bone strain levels on implant stability and bone remodeling at two different implantation times was investigated in a rabbit model. Methods Two different test implants with a diametrical expansion of 0.15 mm (group A) and 0.05 mm (group B) creating initial static bone strains of 0.045 and 0.015, respectively. The implants were inserted in the proximal tibial metaphysis of 24 rabbits to observe the biological response at implant removal. Both groups were compared to control implants (group C), with no diametrical increase. The insertion torque (ITQ) was measured to represent the initial stability and the removal torque (RTQ) was measured to analyze the effect that static strain had on implant stability and bone remodeling after 3 and 13 days of implantation time. Results The ITQ and the RTQ values for test implants were significantly higher for both implantation times compared to control implants. A selection of histology samples was prepared to measure bone to implant contact (BIC). There was a tendency that the BIC values for test implants were higher compared to control implants. Conclusion These findings suggest that increased static bone strain creates higher implant stability at the time of insertion, and this increased stability is maintained throughout the observed period.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

animal model
bone resorption
implant stability

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view