Fracture strength of low translucent and high translucent monolithic zirconia crowns with different thicknesses

Arneryd, Philip (author)
Kindblom, Annika (author)
Larsson, Christel (author)
Malmö högskola,Odontologiska fakulteten (OD)
 (creator_code:org_t)
Swedish Dental Association, 2014
2014
English.
In: Swedish Dental Journal. - : Swedish Dental Association. - 0347-9994. ; 38:4, s. 195-195
  • Journal article (other academic/artistic)
Abstract Subject headings
Close  
  • Objective. The aim of the study was to examine the fracture strength of fully anatomical monolithic high translucent Y-TZP, yttria-stabilized tetragonal zirconia polycrystal, crowns and to compare them with monolithic low translucent Y-TZP crowns in different thicknesses. Materials and methods. 80 standardized crowns were made out of a master model resembling a first mandibular molar made in composite material; 40 crowns made of Lava Zirconia by 3M ESPE, a monolithic low translucent Y-TZP material, and 40 crowns made of Lava Plus by 3M ESPE, a monolithic high translucent Y-TZP material. In each group ten crowns of the thicknesses 1.0 mm, 0.7 mm, 0.5 mm and 0.3 mm were made. All crowns underwent thermocycling and preload to simulate aging and normal wear. Finally the specimens were placed in a testing jig and underwent load to fracture. Results. No significant difference was found when comparing the two materials. When comparing the materials in each thickness a significant difference was found in the 0.5 mm group where the high translucent YTZ-P had a higher mean fracture strength value. A significant difference was seen between the different thicknesses within both groups. The strength increased with added thicknesses. Conclusions. The low translucent and high translucent monolithic YTZ-P perform equally well. The use of high translucent monolithic Y-TZP could result in more aesthetic results and the minimal invasive preparation could lead to a reduction in biological complications. This could be beneficial for the patient since the results suggest that even a thin restoration sustains reasonable load in an in vitro environment. Clinical studies are needed to confirm this suggestion.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publication and Content Type

vet (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Arneryd, Philip
Kindblom, Annika
Larsson, Christe ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Swedish Dental J ...
By the university
Malmö University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view