SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:miun-10092"
 

Search: onr:"swepub:oai:DiVA.org:miun-10092" > In Vivo Detection o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

In Vivo Detection of a pH-Sensitive Nitroxide in the Rat Stomach by Low-Field ESR-Based Techniques

Koptioug, Andrei, 1956- (author)
Department of Biomedical Physics and Bioengineering, University of Aberdeen, Aberdeen, UK
Foster, Margaret (author)
Grigor’ev, Igor (author)
show more...
Lurie, David (author)
Khramtsov, Valerij (author)
McCallum, S. (author)
Panagiotelis, I. (author)
Nicholson, I. (author)
show less...
 (creator_code:org_t)
2003-02-14
2003
English.
In: Magnetic Resonance in Medicine. - : Wiley InterScience. - 0740-3194 .- 1522-2594. ; 49:3, s. 558-567
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear polarization (FC-DNP) for in vitro and in vivo measurements, and radiofrequency (RF)- and X-band ESR for comparisons in vitro. The spin probe was hexamethyl imidazolidine (HMI) with a pK of 4.6. All techniques detected HMI. Detection by FC-DNP implies coupling between the free radical and solvent water spins. Separations between the three spectral lines of the nitroxide radical, relative to measurement frequency, were consistent with theory. The overall spectrum width from unprotonated HMI (pH > pK) was greater than that from protonated agent (pH < pK). This was observed in vitro and in vivo. Longer-term studies showed that HMI is detectable and has the same spectral width (i.e., is at the same pH) up to 2 hr after gavage into the stomach, although the magnitude of the signal decreases rapidly during the first hour. These findings demonstrate the suitability of LODESR and FC-DNP for monitoring HMI and measuring pH in vivo. These techniques would be useful for monitoring disease and drug pharmacology in the living system.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Keyword

in vivo; in-vitro; experimental; measurements; rat; ESR; spin probe; free radical
Physiology and pharmacology
Fysiologi och farmakologi
Molecular physics
Molekylfysik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view