SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:miun-23400"
 

Search: onr:"swepub:oai:DiVA.org:miun-23400" > Spatial resolution ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Spatial resolution in a multi-focus plenoptic camera

Damghanian, Mitra, 1978- (author)
Mittuniversitetet,Avdelningen för informations- och kommunikationssystem,Realistic 3D
Olsson, Roger (author)
Mittuniversitetet,Avdelningen för informations- och kommunikationssystem,Realistic3D
Sjöström, Mårten (author)
Mittuniversitetet,Avdelningen för informations- och kommunikationssystem,Realistic3D
show more...
Erdmann, Arne (author)
Raytrix Gmbh
Perwass, Christian (author)
Raytrix Gmbh
show less...
 (creator_code:org_t)
IEEE conference proceedings, 2014
2014
English.
In: IEEE International Conference on Image Processing, ICIP 2014. - : IEEE conference proceedings. - 9781479957514 ; , s. 1932-1936
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Evaluation of the state of the art plenoptic cameras is necessary for design and application purposes. In this work, spatial resolution is investigated in a multi-focus plenoptic camera using two approaches: empirical and model-based. The Raytrix R29 plenoptic camera is studied which utilizes three types of micro lenses with different focal lengths in a hexagonal array structure to increase the depth of field. The modelbased approach utilizes the previously proposed sampling pattern cube (SPC) model for representation and evaluation of the plenoptic capturing systems. For the experimental resolution measurements, spatial resolution values are extracted from images reconstructed by the provided Raytrix reconstruction method. Both the measurement and the SPC model based approaches demonstrate a gradual variation of the resolution values in a wide depth range for the multi focus R29 camera. Moreover, the good agreement between the results from the model-based approach and those from the empirical approach confirms suitability of the SPC model in evaluating high-level camera parameters such as the spatial resolution in a complex capturing system as R29 multi-focus plenoptic camera.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)

Keyword

Plenoptics
spatial resolution
camera evaluation

Publication and Content Type

ref (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view