Diagnosis of buildings' thermal performance - a quantitative method using thermography under non-steady state heat flow

Danielski, Itai, 1973- (author)
Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande,Ekoteknik
Fröling, Morgan (author)
Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande,Ekoteknik
 (creator_code:org_t)
Elsevier BV, 2015
2015
English.
In: Energy Procedia. - : Elsevier BV. - 1876-6102. ; 83, s. 320-329
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • This study describes a quantitative method using thermography to measure the thermal performance of complete building envelope elements that are subjected to non-steady state heat flow. The method presumes that thermal properties of external walls, like conductivity, could still be obtained by a linear regression over values of independent measurements. And therefore could be used during fluctuating indoor and outdoor thermal conditions. The method is divided into two parts. First, the convection heat transfer coefficient is measured by heat flux meters (HFM) and thermography. And then, the overall heat transfer coefficient of a complete building element is measured by thermography to include all non-uniformities.In this study the thermal performance of a 140 mm thick laminated timber wall was measured. The wall was subjected to the outdoor weather conditions in Östersund, Sweden during January and February. The measurement values were found to have a large disparity as expected due to the rapid change in weather conditions. But still a linear regression with low confidence interval was obtained. The thermography results from a small uniform wall segment were validated with HFM measurements and 4% difference was found, which suggest that the two methods could be equally effective. Yet, thermography has the advantage of measuring surface temperature over large area of building element. The overall heat transfer coefficient of a large wall area was found to be 11% higher in comparison to the HFM measurements. This indicates that thermography could provide a more representative result as it captures areas of imperfections, point and linear thermal bridges.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Annan samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Other Civil Engineering (hsv//eng)

Keyword

heat transfer coefficient
convection
thermal transmittance
conductivity
infrared imaging

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Danielski, Itai, ...
Fröling, Morgan
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Mechanical Engin ...
and Energy Engineeri ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Other Civil Engi ...
Articles in the publication
Energy Procedia
By the university
Mid Sweden University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view