SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:miun-328"
 

Search: onr:"swepub:oai:DiVA.org:miun-328" > Evaluation of an In...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Evaluation of an Integrated Fourier-Transform Spectrometer Utilizing a Lateral Effect Position Sensitive Detector with a Multi-Channel Fabry-Perot Interferometer

Andersson, Henrik (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division
Manuilskiy, Anatoliy (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division
Thungström, Göran (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division
show more...
Nilsson, Hans-Erik (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)
show less...
 (creator_code:org_t)
2008-02-25
2008
English.
In: Measurement science and technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 19:4, s. 045306-
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The basis of this paper is the evaluation of an integrated multi-channel Fourier-transform (FT) spectrometer based on a multi-channel wedge Fabry-Perot interferometer and a one-dimensional lateral effect position sensitive detector (PSD). The use of a PSD for an interferogram readout allows for a simple scanning mechanism with no requirement for any position reference. The use of a wedge-shaped interferometer makes it possible to integrate it directly onto the PSD surface, thus producing a very compact spectrometer. The capabilities of the spectrometer are demonstrated by absorption spectral measurements using a reference sample. In addition, spectral measurements on 532 nm DPSS and 632.8 nm He-Ne lasers are presented. The resolution of the spectrometer is approximately 5 nm. The evaluated spectrometer set-up can be used in applications where compact and low cost spectrometers are required, such as in process control and in education. Further, it is shown that there are deteriorations in very high accuracy position measurements, which are caused by changes in incident light intensity. A model describing the above-mentioned nonlinearities was developed based on analysing the equivalent circuit for PSDs and parameters such as leakage current and serial resistance. Additionally, a method is proposed to assist in the reduction of the nonlinearity caused by this effect.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

Electrical engineering, electronics and photonics
Elektroteknik, elektronik och fotonik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Andersson, Henri ...
Manuilskiy, Anat ...
Thungström, Göra ...
Nilsson, Hans-Er ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
Articles in the publication
Measurement scie ...
By the university
Mid Sweden University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view