SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:miun-42724"
 

Search: onr:"swepub:oai:DiVA.org:miun-42724" > Anaerobic Capacity ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Anaerobic Capacity in Running : The Effect of Computational Method

Andersson, Erik, 1984- (author)
Mittuniversitetet,Institutionen för hälsovetenskap,UiT The Arctic University of Norway, Tromsø, Norway,Nationellt Vintersportcentrum
Björklund, Glenn, 1972- (author)
Mittuniversitetet,Institutionen för hälsovetenskap,Nationellt Vintersportcentrum
McGawley, Kerry, 1978- (author)
Mittuniversitetet,Institutionen för hälsovetenskap,Nationellt Vintersportcentrum
 (creator_code:org_t)
2021-08-04
2021
English.
In: Frontiers in Physiology. - : Frontiers Media S.A.. - 1664-042X. ; 12:August, s. 1-13
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Introduction: To date, no study has compared anaerobic capacity (AnC) estimates computed with the maximal accumulated oxygen deficit (MAOD) method and the gross energy cost (GEC) method applied to treadmill running exercise.Purpose: Four different models for estimating anaerobic energy supply during treadmill running exercise were compared.Methods: Fifteen endurance-trained recreational athletes performed, after a 10-min warm-up, five 4-min stages at ∼55–80% of peak oxygen uptake, and a 4-min time trial (TT). Two linear speed-metabolic rate (MR) regression models were used to estimate the instantaneous required MR during the TT (MRTT_req), either including (5+YLIN) or excluding (5-YLIN) a measured Y-intercept. Also, the average GEC (GECAVG) based on all five submaximal stages, or the GEC based on the last submaximal stage (GECLAST), were used as models to estimate the instantaneous MRTT_req. The AnC was computed as the difference between the MRTT_req and the aerobic MR integrated over time.Results: The GEC remained constant at ∼4.39 ± 0.29 J⋅kg–1⋅m–1 across the five submaximal stages and the TT was performed at a speed of 4.7 ± 0.4 m⋅s–1. Compared with the 5-YLIN, GECAVG, and GECLAST models, the 5+YLIN model generated a MRTT_req that was ∼3.9% lower, with corresponding anaerobic capacities from the four models of 0.72 ± 0.20, 0.74 ± 0.16, 0.74 ± 0.15, and 0.54 ± 0.14 kJ⋅kg–1, respectively (F1.07,42 = 13.9, P = 0.002). The GEC values associated with the TT were 4.22 ± 0.27 and 4.37 ± 0.30 J⋅kg–1⋅m–1 for 5+YLIN and 5-YLIN, respectively (calculated from the regression equation), and 4.39 ± 0.28 and 4.38 ± 0.27 J⋅kg–1⋅m–1 for GECAVG and GECLAST, respectively (F1.08,42 = 14.6, P < 0.001). The absolute typical errors in AnC ranged between 0.03 and 0.16 kJ⋅kg–1 for the six pair-wise comparisons and the overall standard error of measurement (SEM) was 0.16 kJ⋅kg–1.Conclusion: These findings demonstrate a generally high disagreement in estimated anaerobic capacities between models and show that the inclusion of a measured Y-intercept in the linear regression (i.e., 5+YLIN) is likely to underestimate the MRTT_req and the GEC associated with the TT, and hence the AnC during maximal 4-min treadmill running.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Andersson, Erik, ...
Björklund, Glenn ...
McGawley, Kerry, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Health Sciences
and Sport and Fitnes ...
Articles in the publication
Frontiers in Phy ...
By the university
Mid Sweden University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view