Reducing dose in urography while maintaining image quality - a comparison of storage phosphor plates and a flat-panel detector

Jansson, Margareta (author)
Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
Geijer, Håkan (author)
Örebro universitet,Institutionen för klinisk medicin,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
Persliden, Jan (author)
Östergötlands Läns Landsting,Linköpings universitet,Örebro universitet,Institutionen för klinisk medicin,Hälsouniversitetet,Medicinsk radiofysik,Radiofysikavdelningen
show more...
Andersson, Torbjörn (author)
Örebro universitet,Institutionen för klinisk medicin,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
show less...
 (creator_code:org_t)
2005-04-27
2006
English.
In: European Radiology. - Berlin / Heidelberg : Springer. - 0938-7994 .- 1432-1084. ; 16:1, s. 221-226
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The introduction of new flat-panel detector technology often forces us to accept too high dose levels as proposed by the manufacturers. We need a tool to compare the image quality of a new system with the accepted standard. The aim of this study was to obtain a comparable image quality for two systems-storage phosphor plates and a flat-panel system using intravenous urography (IVU) as a clinical model. The image quality figure was calculated using a contrast-detail phantom (CDRAD) for the two evaluated systems. This allowed us to set a dose for the flat-panel system that gave equivalent image quality to the storage phosphor plates. This reduced detector dose was used in an evaluation of clinical images to find out if the dose reduction from the phantom study indeed resulted in images of equal clinical image quality. The image quality was assessed using image criteria of the European guidelines for IVU with visual grading analysis. Equivalent image quality in image pairs was achieved at 30% of the dose. The CDRAD contrast-detail phantom makes it possible to find dose levels that give equal image quality using different imaging systems.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

MEDICINE
MEDICIN
Diagnostic radiology
Diagnostisk radiologi
Medicine
medicin
Digital radiography

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view