Cardiovascular magnetic resonance imaging and transthoracic echocardiography in the assessment of stenotic aortic valve area : a comparative study

Dimitriou, Praxitelis (author)
Department of Radiology, Örebro University Hospital , Örebro, Sweden
Kähäri, Anders (author)
Department of Clinical Physiology, Örebro University Hospital , Örebro, Sweden
Emilsson, Kent, 1963- (author)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Clinical Physiology, Örebro University Hospital , Örebro, Sweden
show more...
Thunberg, Per, 1968- (author)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Medical Physics, Örebro University Hospital, Örebro, Sweden
show less...
 (creator_code:org_t)
2012-11-01
2012
English.
In: Acta Radiologica. - London, United Kingdom : Royal Society of Medicine Press. - 0284-1851 .- 1600-0455. ; 53:9, s. 995-1003
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Magnetic resonance (MR) imaging and echocardiography both allow assessment of aortic valve stenosis. In MR the aortic valve area (AvA) is measured using planimetry while in transthoracic echocardiography (TTE) AvA is usually calculated by applying the continuity equation.Purpose: To compare the measured stenotic aortic valve areas using five different MR-acquisition alternatives with the corresponding area values calculated by TTE.Material and Methods: The aortic valve was imaged in 14 patients, with diagnosed aortic valve stenosis, using balanced steady state free precession (bSSFP) gradient echo (GE) and phase contrast imaging (PC). Three adjacent slices were planned to encompass the aortic valve and the aortic valve area was measured using planimetry. The two sets of complex valued images generated by the PC sequence formed three kinds of images that could be used for aortic valve area measurements: the magnitude image (PC/Mag), the modulus (PCA/M), and phase difference (PCA/P) between the two complex images, respectively. The valve area from TTE was calculated using the continuity equation. A cut-off of <1.0 cm(2) was used as a criteria for severe stenosis.Results: The mean area differences between the different MR acquisitions and TTE method were -0.05 ± 0.37 cm(2) (GE), -0.18 ± 0.46 cm(2) (bSSFP), 0.27 ± 0.43 cm(2) (PC/Mag), 0.15 ± 0.32 cm(2) (PCA/P), and 0.26 ± 0.27 cm(2) (PCA/M). The valve area was significantly overestimated using PCA/M that, in turn, implied a significant underestimation of the aortic valve stenosis severity compared to the assessments using TTE.Conclusion: The smallest area valve difference between TTE and an MR-acquisition alternative is obtained with gradient echo images. The use of PCA/M leads to significant differences in planimetry measurements of the aortic valve orifice and the gradation of the stenosis severity compared to TTE.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Aortic valve stenosis
gradient echo
phase contrast imaging
balanced steady state free precession
Radiologi
Radiology

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Dimitriou, Praxi ...
Kähäri, Anders
Emilsson, Kent, ...
Thunberg, Per, 1 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Acta Radiologica
By the university
Örebro University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view