SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:oru-27174"
 

Search: onr:"swepub:oai:DiVA.org:oru-27174" > Flow and peak veloc...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Flow and peak velocity measurements in patients with aortic valve stenosis using phase contrast MR accelerated with k-t BLAST

Thunberg, Per, 1968- (author)
Department of Medical Physics, Örebro University Hospital, Örebro, Sweden
Emilsson, Kent, 1963- (author)
Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden
Rask, Peter (author)
Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden
show more...
Kähäri, Anders (author)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
show less...
 (creator_code:org_t)
Clare, Ireland : Elsevier, 2012
2012
English.
In: European Journal of Radiology. - Clare, Ireland : Elsevier. - 0720-048X .- 1872-7727. ; 81:9, s. 2203-2207
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: To investigate the accuracy of velocity measurements in patients with aortic valve stenosis using phase contrast (PC) imaging accelerated with SENSE (Sensitivity Encoding) and k-t BLAST (Broad-use Linear Acquisition Speed-up Technique).Methods: Accelerated quantitative breath hold PC measurements, using SENSE and k-t BLAST, were performed in twelve patients whose aortic valve stenosis had been initially diagnosed using echocardiography. Stroke volume (SV) and peak velocity measurements were performed on each subject in three adjacent slices using both accelerating methods.Results: The peak velocities measured with PC MRI using SENSE were -8.0±9.5% lower (p<0.01) compared to the peak velocities measured with k-t BLAST and the correlation was r=0.83. The stroke volumes when using SENSE were slightly higher 0.4±17.1 ml compared to the SV obtained using k-t BLAST but the difference was not significant (p>0.05).Conclusions In this study higher peak velocities were measured in patients with aortic stenosis when combining k-t BLAST with PC MRI compared to PC MRI using SENSE. A probable explanation of this difference is the higher temporal resolution achieved in the k-t BLAST measurement. There was, however, no significant difference between calculated SV based on PC MRI using SENSE and k-t BLAST, respectively.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Aortic valve
stenosis
k-t BLAST
SENSE
phase contrast imaging
Radiologi
Radiology

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Thunberg, Per, 1 ...
Emilsson, Kent, ...
Rask, Peter
Kähäri, Anders
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
European Journal ...
By the university
Örebro University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view