SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:oru-30101"
 

Search: onr:"swepub:oai:DiVA.org:oru-30101" > Slower progression ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Slower progression of atherosclerosis in vein grafts harvested with 'no touch' technique compared with conventional harvesting technique in coronary artery bypass grafting : an angiographic and intravascular ultrasound study

Johansson, Benny L. (author)
Örebro universitet,Institutionen för hälsovetenskap och medicin
Souza, Domingos S. R. (author)
Bodin, Lennart (author)
Örebro universitet,Institutionen för hälsovetenskap och medicin
show more...
Filbey, Derek (author)
Loesch, Andrzej (author)
Geijer, Håkan, 1961- (author)
Department of Thoracic Radiology, Örebro University Hospital, Örebro, Sweden
Bojo, Leif (author)
show less...
 (creator_code:org_t)
Oxford University Press (OUP), 2010
2010
English.
In: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940 .- 1873-734X. ; 38:4, s. 414-419
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives: In a long-term randomised coronary artery bypass grafting (CABG) study, the patency rate using a new 'no touch' (NT) vein-graft preparation technique was superior to the conventional (C) technique. This cineangiographic and intravascular ultrasound (IVUS) substudy examined possible mechanisms.Methods: A total of 45 patients (118 grafts) in the NT group and 46 patients (112 grafts) in the C group had patent grafts at short-term follow-up after 18 months. Thirty-seven patients (91 grafts) in the NT group and 37 patients (77 grafts) in the C group had patent grafts at long-term follow-up after 8 5 years, and were evaluated on a scale from 0 (normal) to 2 (significant stenosis) by cineangiogram. IVUS was performed in 15 NT grafts and 14 C grafts in the short-term follow-up, and 27 NT grafts and 26 C grafts in the long-term follow-up, in grafts considered normal by the cineangiogram. The grafts were evaluated with respect to lumen volume, intimal thickness, incidence of plaque and plaque components.Results: In the short-term follow-up, the cineangiogram showed more normal grafts (89.0% in the NT group compared with 75.0% in the C group), and the number of grafts with stenosis was 11.0% in the NT group compared with 25.0% in the C group (p = 0.006). IVUS showed less mean intimal thickness (0.43 (0.07) mm vs 0.52 (0.08) mm; p = 0.03), less grafts with considerable intimal hyperplasia (>= 0.9 mm; 20% vs 78.6%; p = 0.011) and fewer patients with considerable hyperplasia (>= 0.9 mm; 25% vs 100%; p = 0.007). In the long-term follow-up, the cineangiogram showed more normal grafts, with 91.2% in the NT group compared with 83.1% in the C group; there were fewer grafts with significant stenosis, with 7.7% in the NT group compared with 15 6% in the C group (p = 0.14). IVUS showed fewer grafts containing multiple plaques (14.8% vs 50%; p = 0.008), less advanced plaque with lipid (11.8% vs 63.9%; p = 0.0004) and less maximal plaque thickness (1.04 (0.23) mm vs 1.32 (0.25) mm; p = 0.02) in the NT group compared with the C group.Conclusion: The superior long-term patency rate using the NT vein-graft technique at CABG could be explained by a significantly slower progression of atherosclerosis. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Keyword

CABG
Coronary artery bypass grafts
IVUS
Ischaemic heart disease
Revascularisation
Medicine
Medicin

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view