SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:oru-33269"
 

Search: onr:"swepub:oai:DiVA.org:oru-33269" > The No-Touch Saphen...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003707naa a2200397 4500
001oai:DiVA.org:oru-33269
003SwePub
008140123s2013 | |||||||||||000 ||eng|
009oai:prod.swepub.kib.ki.se:127074821
024a https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-332692 URI
024a https://doi.org/10.1016/j.athoracsur.2013.01.1022 DOI
024a http://kipublications.ki.se/Default.aspx?queryparsed=id:1270748212 URI
040 a (SwePub)orud (SwePub)ki
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Dreifaldt, Matsu Örebro universitet,Institutionen för hälsovetenskap och medicin,Region Örebro län,Department of Cardiovascular Surgery, Örebro University Hospital, Region Örebro County, Örebro, Sweden4 aut0 (Swepub:oru)msdt
2451 0a The No-Touch Saphenous Vein as the Preferred Second Conduit for Coronary Artery Bypass Grafting
264 1b Elsevier BV,c 2013
338 a print2 rdacarrier
520 a Background: Injury incurred while saphenous veins are being obtained results in poor graft patency and impairs the results of coronary artery bypass grafting. A novel method of obtaining veins, the no-touch technique, has shown improved long-term saphenous vein graft patency.Methods: This randomized trial included 108 patients undergoing coronary artery bypass grafting and compared the patency of no-touch saphenous vein with that of radial artery grafts. Each patient was assigned to receive one no-touch saphenous vein and one radial artery graft to either the left or the right coronary territory to complement the left internal thoracic artery.Results: Angiography was performed in 99 patients (92%) at a mean of 36 months postoperatively. Graft and grafted coronary artery patency was evaluated. The patency of grafts for no-touch saphenous vein and radial artery was 94% versus 82% (p = 0.01), respectively. The patency of coronary arteries grafted with no-touch saphenous vein and radial artery grafts was 95% versus 84% (p = 0.005), respectively. Eighty-nine of 96 (93%) left internal thoracic artery grafts were patent.Conclusions: No-touch saphenous vein grafts showed a significantly higher patency rate than the radial artery grafts and the patency was comparable to the patency for left internal thoracic artery grafts. This highlights the improvement in saphenous vein graft quality with the no-touch technique and increases the number of situations in which saphenous veins may be preferable to radial artery grafts as conduits in coronary artery bypass grafting.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Kardiologi0 (SwePub)302062 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cardiac and Cardiovascular Systems0 (SwePub)302062 hsv//eng
653 a Medicine
653 a Medicin
700a Mannion, John D.u Department of Surgery, Bayhealth Medical Center, Dover DE, USA4 aut
700a Bodin, Lennartu Karolinska Institutet,Örebro universitet,Handelshögskolan vid Örebro Universitet4 aut0 (Swepub:oru)lbn
700a Olsson, Hans4 aut
700a Zagozdzon, Leszek4 aut
700a Souza, Domingos S. R.u Region Örebro län4 aut0 (Swepub:oru)OUH-do1so
710a Örebro universitetb Institutionen för hälsovetenskap och medicin4 org
773t Annals of Thoracic Surgeryd : Elsevier BVg 96:1, s. 105-111q 96:1<105-111x 0003-4975x 1552-6259
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-33269
8564 8u https://doi.org/10.1016/j.athoracsur.2013.01.102
8564 8u http://kipublications.ki.se/Default.aspx?queryparsed=id:127074821

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view