SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:oru-82938"
 

Search: onr:"swepub:oai:DiVA.org:oru-82938" > Patient-Perceived O...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Patient-Perceived Outcome After Total Wrist Arthroplasty : A Single-Center Study of 223 Cases

Sagerfors, Marcus, MD, PhD, 1977- (author)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Hand Surgery
Brus, Ole, 1982- (author)
Örebro universitet,Institutionen för medicinska vetenskaper
Pettersson, Kurt (author)
Department of Hand Surgery, Faculty of Medicine and Health, Örebro University, Sweden
 (creator_code:org_t)
2016-09-26
2016
English.
In: Hand. - : Sage Publications. - 1558-9447 .- 1558-9455. ; 11:1_suppl, s. 2S-2S
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: Total wrist arthroplasty (TWA) is an established surgical treatment for wrist arthritis. The aim of the investigation is to report patient-perceived outcome measures after TWA operated at a single referral center in Sweden.Methods: In a cohort study with prospective collection of data, we evaluated 193 consecutive patients with a TWA (223 wrists) preoperatively, 1 and 5 years postoperatively. The wrists were implanted between 2002 and 2014. Outcome measures studied were range of motion (ROM), visual analogue scale (VAS) pain scores, hand grip strength, and patient-related outcome measures. Secondary outcome measures included implant survivorship, which was estimated using the Kaplan-Meier method, and radiographic loosening 5 years postoperatively.Results: VAS pain scores and patient-related outcome measures improved significantly for all TWAs. Improved hand grip strength was noted for all TWAs except Universal 2. ROM improved somewhat, especially for the Biax and Maestro TWAs. Cumulative implant survival after 5 years was 99% for Remotion, 95% for Maestro, and 84% for Biax. Radiographic loosening was present in 26% of the Biax cases, 18% of the Remotion cases, and 2% of the Maestro cases.Conclusions: All TWA designs in this study offer a high level of patient satisfaction. The design of the implant may affect patient-perceived outcome 5 years postoperatively. Good mid to long-term results can be achieved in patients undergoing TWA.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Hand (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Sagerfors, Marcu ...
Brus, Ole, 1982-
Pettersson, Kurt
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Orthopaedics
Articles in the publication
Hand
By the university
Örebro University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view