Long-term stability of an injection-molded zirconia bone-level implant : A testing protocol considering aging kinetics and dynamic fatigue

Spies, B. C. (author)
University of Freiburg, Germany
Maass, M. E. (author)
University of Freiburg, Germany
Adolfsson, Erik (author)
RISE,IVF
show more...
Sergo, V. (author)
University of Trieste, Italy
Kiemle, T. (author)
University of Tuebingen, Germany
Berthold, C. (author)
University of Tuebingen, Germany
Gurian, E. (author)
University of Trieste, Italy
Fornasaro, S. (author)
University of Trieste, Italy
Vach, K. (author)
University of Freiburg, Germany
Kohal, R. -J (author)
University of Freiburg, Germany
show less...
 (creator_code:org_t)
Elsevier BV, 2017
2017
English.
In: Dental Materials. - : Elsevier BV. - 0109-5641. ; 33:8, s. 954-965
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective Separately addressing the fatigue resistance (ISO 14801, evaluation of final product) and aging behavior (ISO 13356, standardized sample) of oral implants made from yttria-stabilized zirconia proved to be insufficient in verifying their long-term stability, since (1) implant processing is known to significantly influence transformation kinetics and (2) aging, up from a certain level, is liable to decrease fatigue resistance. Therefore, the aim of this investigation was to apply a new testing protocol considering environmental conditions adequately inducing aging during dynamic fatigue. Methods Zirconia implants were dynamically loaded (107 cycles), hydrothermally aged (85°, 60 days) or subjected to both treatments simultaneously. Subsequent, monoclinic intensity ratios (Xm) were obtained by locally resolved X-ray microdiffraction (μ-XRD2). Transformation propagation was monitored at cross-sections by μ-Raman spectroscopy and scanning electron microscopy (SEM). Finally, implants were statically loaded to fracture. Linear regression models (fracture load) and mixed models (Xm) were used for statistical analyses. Results All treatments resulted in increased fracture load (p ≤ 0.005), indicating the formation of transformation induced compressive stresses around surface defects during all treatment modalities. However, only hydrothermal and combinational treatment were found to increase Xm (p < 0.001). No change in Xm was observed for solely dynamically loaded samples (p ≥ 0.524). Depending on the variable observed, a monoclinic layer thickness of 1–2 μm (SEM) or 6–8 μm (Raman spectroscopy) was measured at surfaces exposed to water during treatments. Significance Hydrothermal aging was successfully induced during dynamic fatigue. Therefore, the presented setup might serve as reference protocol for ensuring pre-clinically long-term reliability of zirconia oral implants.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering (hsv//eng)

Keyword

Ceramics
Crystallography
Dental implant
Raman spectroscopy
Scanning electron microscopy
X-ray diffraction
Zirconia

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view