Search: onr:"swepub:oai:DiVA.org:ri-35154" >
Broad-range hydroge...
Broad-range hydrogel-based pH sensor with capacitive readout manufactured on a flexible substrate
-
- Hammarling, Krister, 1968- (author)
- Mittuniversitetet,Avdelningen för elektronikkonstruktion
-
- Engholm, Magnus (author)
- Mittuniversitetet,Avdelningen för elektronikkonstruktion
-
- Andersson, Henrik, 1975- (author)
- Mittuniversitetet,Avdelningen för elektronikkonstruktion
-
show more...
-
- Sandberg, Mats (author)
- Mittuniversitetet,RISE,Acreo,Mid Sweden University, Sweden,Avdelningen för elektronikkonstruktion,RISE Acreo AB, Bredgatan 33, 601 17 Norrköping, Sweden
-
- Nilsson, Hans-Erik, 1965- (author)
- Mittuniversitetet,Avdelningen för elektronikkonstruktion
-
show less...
-
(creator_code:org_t)
- 2018-07-25
- 2018
- English.
-
In: Chemosensors. - Basel, Switzerland : MDPI AG. - 2227-9040. ; 6:3
- Related links:
-
https://ri.diva-port... (primary) (Raw object)
-
show more...
-
https://www.mdpi.com...
-
https://doi.org/10.3...
-
http://www.mdpi.com/...
-
https://miun.diva-po... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.3...
-
https://urn.kb.se/re...
-
show less...
Abstract
Subject headings
Close
- Environmental monitoring of land, water and air, is an area receiving greater attention because of human health and safety concerns. Monitoring the type of pollution and concentration levels is vital, so that appropriate contingency plans can be determined. To effectively monitor the environment, there is a need for new sensors and sensor systems that suits these type of measurements. However, the diversity of sensors suitable for low, battery powered- and large area sensor systems are limited. We have manufactured and characterized a flexible pH sensor using laser processing and blade coating techniques that is able to measure pH between 2.94 and 11.80. The sensor consists of an interdigital capacitance with a pH sensitive hydrogel coating. Thin sensors can reach 95% of their final value value within 3 min, and are stable after 4 min. Good repeatability was achieved in regard to cycling of the sensor with different pH and multiple measurements from dry state. We have also studied the relation between an interdigital capacitance penetration depth and hydrogels expansion. We believe that our passive sensor is suitable to be used in low power and large area sensor networks.
Subject headings
- NATURVETENSKAP -- Fysik -- Den kondenserade materiens fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Condensed Matter Physics (hsv//eng)